Myopia Control during Orthokeratology Lens Wear in Children Using a Novel Study Design

角膜塑形术 自折射 医学 隐形眼镜 眼科 验光服务 折射误差 前瞻性队列研究 镜头(地质) 交叉研究 角膜地形图 角膜 眼病 外科 光学 物理 替代医学 病理 安慰剂
作者
Helen A. Swarbrick,Ahmed Alharbi,Kathleen Watt,Edward Lum,Pauline Kang
出处
期刊:Ophthalmology [Elsevier]
卷期号:122 (3): 620-630 被引量:211
标识
DOI:10.1016/j.ophtha.2014.09.028
摘要

Purpose To investigate the effect of overnight orthokeratology (OK) contact lens wear on axial length growth in East Asian children with progressive myopia. Design A prospective, randomized, contralateral-eye crossover study conducted over a 1-year period. Participants We enrolled 26 myopic children (age range, 10.8–17.0 years) of East Asian ethnicity. Methods Subjects were fitted with overnight OK in 1 eye, chosen at random, and conventional rigid gas-permeable (GP) lenses for daytime wear in the contralateral eye. Lenses were worn for 6 months. After a 2-week recovery period without lens wear, lens–eye combinations were reversed and lens wear was continued for a further 6 months, followed by another 2-week recovery period without lens wear. Axial eye length was monitored at baseline and every 3 months using an IOLMaster biometer. Corneal topography (Medmont E300) and objective refraction (Shin-Nippon NVision-K 5001 autorefractor) were also measured to confirm that OK lens wear was efficacious in correcting myopia. Main Outcome Measurements Axial length elongation and myopia progression with OK were compared with conventional daytime rigid contact lens wear. Results After 6 months of lens wear, axial length had increased by 0.04±0.06 mm (mean ± standard deviation) in the GP eye (P = 0.011) but showed no change (−0.02±0.05 mm) in the OK eye (P = 0.888). During the second 6-month phase of lens wear, in the OK eye there was no change from baseline in axial length at 12 months (−0.04±0.08 mm; P = 0.218). However, in the GP eye, the 12-month increase in axial length was significant (0.09±0.09 mm; P < 0.001). The GP lens-wearing eye showed progressive axial length growth throughout the study. Conclusions These results provide evidence that, at least in the initial months of lens wear, overnight OK inhibits axial eye growth and myopia progression compared with conventional GP lenses. Apparent shortening of axial length early in OK lens wear may reflect the contribution of OK-induced central corneal thinning, combined with choroidal thickening or recovery due to a reduction or neutralization of the myopiogenic stimulus to eye growth in these myopic children. To investigate the effect of overnight orthokeratology (OK) contact lens wear on axial length growth in East Asian children with progressive myopia. A prospective, randomized, contralateral-eye crossover study conducted over a 1-year period. We enrolled 26 myopic children (age range, 10.8–17.0 years) of East Asian ethnicity. Subjects were fitted with overnight OK in 1 eye, chosen at random, and conventional rigid gas-permeable (GP) lenses for daytime wear in the contralateral eye. Lenses were worn for 6 months. After a 2-week recovery period without lens wear, lens–eye combinations were reversed and lens wear was continued for a further 6 months, followed by another 2-week recovery period without lens wear. Axial eye length was monitored at baseline and every 3 months using an IOLMaster biometer. Corneal topography (Medmont E300) and objective refraction (Shin-Nippon NVision-K 5001 autorefractor) were also measured to confirm that OK lens wear was efficacious in correcting myopia. Axial length elongation and myopia progression with OK were compared with conventional daytime rigid contact lens wear. After 6 months of lens wear, axial length had increased by 0.04±0.06 mm (mean ± standard deviation) in the GP eye (P = 0.011) but showed no change (−0.02±0.05 mm) in the OK eye (P = 0.888). During the second 6-month phase of lens wear, in the OK eye there was no change from baseline in axial length at 12 months (−0.04±0.08 mm; P = 0.218). However, in the GP eye, the 12-month increase in axial length was significant (0.09±0.09 mm; P < 0.001). The GP lens-wearing eye showed progressive axial length growth throughout the study. These results provide evidence that, at least in the initial months of lens wear, overnight OK inhibits axial eye growth and myopia progression compared with conventional GP lenses. Apparent shortening of axial length early in OK lens wear may reflect the contribution of OK-induced central corneal thinning, combined with choroidal thickening or recovery due to a reduction or neutralization of the myopiogenic stimulus to eye growth in these myopic children.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
02完成签到,获得积分10
1秒前
mao发布了新的文献求助10
2秒前
3秒前
平淡紫夏发布了新的文献求助10
3秒前
3秒前
慈祥的丹寒完成签到 ,获得积分10
3秒前
sun0115完成签到 ,获得积分10
4秒前
科研通AI6.1应助你好采纳,获得10
4秒前
格子浅唱初夏完成签到,获得积分10
5秒前
BBH完成签到,获得积分10
7秒前
进击的水稻完成签到 ,获得积分10
7秒前
Echo完成签到 ,获得积分10
7秒前
黑多羊发布了新的文献求助10
8秒前
调皮善斓完成签到,获得积分10
8秒前
myf发布了新的文献求助10
9秒前
整齐的海云完成签到,获得积分10
10秒前
我666完成签到,获得积分10
10秒前
苏某坡完成签到 ,获得积分10
10秒前
10秒前
Sablon应助crookshanks88采纳,获得30
11秒前
万能图书馆应助肉卷采纳,获得10
11秒前
11秒前
02发布了新的文献求助20
13秒前
13秒前
阳光元彤发布了新的文献求助10
13秒前
blue1985完成签到,获得积分10
13秒前
14秒前
15秒前
池鱼应助dsds采纳,获得30
15秒前
SciGPT应助奈者CO采纳,获得10
16秒前
直率绮南发布了新的文献求助20
16秒前
17秒前
Lzh完成签到 ,获得积分10
17秒前
demker发布了新的文献求助10
17秒前
17秒前
18秒前
坚定的电灯胆完成签到,获得积分20
18秒前
杨逸尔发布了新的文献求助10
19秒前
19秒前
迪士尼在逃后母完成签到,获得积分10
19秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Kinesiophobia : a new view of chronic pain behavior 3000
Les Mantodea de guyane 2500
Signals, Systems, and Signal Processing 510
Discrete-Time Signals and Systems 510
Brittle Fracture in Welded Ships 500
Lloyd's Register of Shipping's Approach to the Control of Incidents of Brittle Fracture in Ship Structures 500
热门求助领域 (近24小时)
化学 材料科学 生物 医学 工程类 计算机科学 有机化学 物理 生物化学 纳米技术 复合材料 内科学 化学工程 人工智能 催化作用 遗传学 数学 基因 量子力学 物理化学
热门帖子
关注 科研通微信公众号,转发送积分 5941046
求助须知:如何正确求助?哪些是违规求助? 7060042
关于积分的说明 15884501
捐赠科研通 5071365
什么是DOI,文献DOI怎么找? 2727885
邀请新用户注册赠送积分活动 1686395
关于科研通互助平台的介绍 1613062