Andrew K. Palmer,Frederick W. Werner,Dennis J. Murphy,Richard R. Glisson
标识
DOI:10.1016/s0363-5023(85)80246-x
摘要
A triaxial electrogoniometer was used to measure functional wrist motion. Wrist motion was evaluated in 10 normal subjects who performed 52 standardized tasks. The wrist joint was found to have three degrees of freedom (flexion-extension, radioulnar deviation, and rotation). The normal functional range of wrist motion is 5° of flexion, 30° of extension, 10° of radial deviation, and 15° of ulnar deviation. A triaxial electrogoniometer was used to measure functional wrist motion. Wrist motion was evaluated in 10 normal subjects who performed 52 standardized tasks. The wrist joint was found to have three degrees of freedom (flexion-extension, radioulnar deviation, and rotation). The normal functional range of wrist motion is 5° of flexion, 30° of extension, 10° of radial deviation, and 15° of ulnar deviation.