亲爱的研友该休息了!由于当前在线用户较少,发布求助请尽量完整地填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!身体可是革命的本钱,早点休息,好梦!

AASM Criteria for Scoring Respiratory Events: Interaction between Apnea Sensor and Hypopnea Definition

呼吸不足 多导睡眠图 安眠药 阻塞性睡眠呼吸暂停 医学 呼吸暂停 睡眠呼吸暂停 心脏病学 内科学 睡眠障碍 失眠症 精神科
作者
Andrew Thornton,Parmjit Singh,Warren R. Ruehland,Peter D. Rochford
出处
期刊:Sleep [Oxford University Press]
被引量:54
标识
DOI:10.5665/sleep.1710
摘要

To examine the impact of using a nasal pressure sensor only vs the American Academy of Sleep Medicine (AASM) recommended combination of thermal and nasal pressure sensors on (1) the apnea index (AI), (2) the apnea-hypopnea index (AHI), where the AHI is calculated using both AASM definitions of hypopnea, and (3) the accuracy of a diagnosis of obstructive sleep apnea (OSA).Retrospective review of previously scored in-laboratory polysomnography.A tertiary-hospital clinical sleep laboratory.One hundred sixty-four consecutive adult patients with a potential diagnosis of OSA, who were examined during a 3-month period.N/A.Studies were scored with and without the use of the oronasal thermal sensor. AIs and AHIs, using the nasal pressure sensor alone (AI(np) and AHI(np)), were compared with those using both a thermal sensor for the detection of apnea and a nasal pressure transducer for the detection of hypopnea (AI(th) and AHI(th)). Comparisons were repeated using the AASM recommended (AASM(rec)) and alternative (AASM(alt)) hypopnea definitions. AI was significantly different when measured from the different sensors, with AI(np) being 51% higher on average. Using the AASM(rec) hypopnea definition, the mean AHI(np) was 15% larger than the AHI(th); with large interindividual differences and an estimated 9.8% of patients having a false-positive OSA diagnosis at a cutpoint of 15 events and 4.3% at 30 events per hour. Using AASM(alt) hypopnea definition, the mean AHI(np) was 3% larger than the AHI(th), with estimated false-positive rates of 4.6% and 2.4%, respectively. The false-negative rate was negligible at 0.1% for both hypopnea definitions.This study demonstrates that using only a nasal pressure sensor for the detection of apnea resulted in higher values of AI and AHI than when the AASM recommended thermal sensor was added to detect apnea. When the AASM(alt) hypopnea definition was used, the differences in AHI and subsequent OSA diagnosis were small and less than when the AASM(rec) hypopnea definition was used. In situations in which a thermal sensor cannot be used, for example, in limited-channel diagnostic devices, the AHI obtained with a nasal pressure sensor alone differs less from the AHI obtained from a polysomnogram that includes a thermal sensor when the AASM(alt) definition rather than the AASM(rec) definition of hypopnea is used. Thus, diagnostic accuracy is impacted both by the absence of the thermal sensor and by the rules used to analyze the polysomnography. Furthermore, where the thermal sensor is unreliable for sections of a study, it is likely that use of the nasal pressure signal to detect apnea will have modest impact.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
3秒前
量子星尘发布了新的文献求助10
1分钟前
万能图书馆应助猫抓板采纳,获得10
1分钟前
1分钟前
猫抓板发布了新的文献求助10
1分钟前
路人应助Magali采纳,获得200
1分钟前
小蘑菇应助猫抓板采纳,获得10
1分钟前
科研通AI2S应助科研通管家采纳,获得10
1分钟前
大园完成签到 ,获得积分10
1分钟前
1分钟前
领导范儿应助Magali采纳,获得150
2分钟前
猫抓板发布了新的文献求助10
2分钟前
昭昭完成签到,获得积分10
2分钟前
2分钟前
Magali发布了新的文献求助150
2分钟前
2分钟前
昭昭发布了新的文献求助10
2分钟前
2分钟前
2分钟前
爆米花应助昭昭采纳,获得10
2分钟前
猫抓板发布了新的文献求助10
2分钟前
共享精神应助猫抓板采纳,获得10
2分钟前
2分钟前
猫抓板发布了新的文献求助10
3分钟前
Qing完成签到 ,获得积分10
3分钟前
JamesPei应助猫抓板采纳,获得10
3分钟前
AixLeft完成签到 ,获得积分10
3分钟前
3分钟前
猫抓板发布了新的文献求助10
3分钟前
把饭拼好给你完成签到 ,获得积分10
4分钟前
善学以致用应助猫抓板采纳,获得10
4分钟前
4分钟前
许晴完成签到,获得积分10
4分钟前
5分钟前
5分钟前
5分钟前
5分钟前
猫抓板发布了新的文献求助10
5分钟前
孤独又灿烂的夜猫子完成签到 ,获得积分10
5分钟前
科研通AI6应助科研通管家采纳,获得10
5分钟前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Translanguaging in Action in English-Medium Classrooms: A Resource Book for Teachers 700
Qualitative Data Analysis with NVivo By Jenine Beekhuyzen, Pat Bazeley · 2024 660
Handbook of Migration, International Relations and Security in Asia 555
Between high and low : a chronology of the early Hellenistic period 500
Exosomes Pipeline Insight, 2025 500
Advanced Memory Technology: Functional Materials and Devices 400
热门求助领域 (近24小时)
化学 材料科学 生物 医学 工程类 计算机科学 有机化学 物理 生物化学 纳米技术 复合材料 内科学 化学工程 人工智能 催化作用 遗传学 数学 基因 量子力学 物理化学
热门帖子
关注 科研通微信公众号,转发送积分 5671228
求助须知:如何正确求助?哪些是违规求助? 4912699
关于积分的说明 15134266
捐赠科研通 4830020
什么是DOI,文献DOI怎么找? 2586614
邀请新用户注册赠送积分活动 1540279
关于科研通互助平台的介绍 1498455