假体周围
医学
外科
关节置换术
全髋关节置换术
股骨
髋关节置换术
作者
Benjamin M. Frye,Keith R. Berend,Michael J. Morris,BFA Joanne Adams,Adolph V. Lombardi
摘要
Background: Modular component options can assist the surgeon in addressing complex femoral reconstructions in total hip arthroplasty by allowing for customization of version control and proximal to distal sizing. We review the early clinical results of a single modular femoral revision system that offers 3 proximal body types, 5 distal stem geometries, and a wide range of offset, sizing and auxiliary options.Methods: A query of our practice’s arthroplasty registry revealed 60 patients (61 hips) who signed an IRB-approved general research consent allowing retrospective review, and underwent total hip arthroplasty performed with the modular femoral revision system between December 2009 and April 2012. There were 35 men (58%) and 25 women (42%). Mean age was 65.1 years (range, 35-94) and BMI was 31.3 kg.m2 (range, 14-53). Procedures were complex primary in 1 hip, conversion in 6 (10%), revision in 32 (53%), and two-staged exchange for infection in 22 (33%). Two-thirds of procedures included complete acetabular revision (n=40), while 31% (19) involved liner change only and 2 were isolated femoral revisions.Results: At an average follow-up of 1.5 years (maximum: 3.7 years) there have been no revisions or failures of the femoral component. Average Harris hip scores (0 to 100 possible) improved from 44.2 preoperatively to 66.0 at most recent evaluation, while the pain component (0 to 44 possible) improved from 15.8 to 31.2. Complications requiring surgical intervention included intraoperative periprosthetic femur fracture in one patient returned to the operating suite same day for open reduction internal fixation, which further required incision and debridement for superficial infection at 1 year postoperative; and two patients with dislocation and fracture of the greater trochanter treated with open reduction, revision of the head and liner, and application of cerclage cables, one of which required removal of a migrated claw 10 months later followed 2 weeks subsequently with incision and debridement for a non-healing wound. Postoperative radiographs were available for review for 59 THA in 58 patients. Analysis of the femoral component revealed satisfactory findings in 50 hips (85%) while 9 had radiographic changes that included bone deficit, osteolysis, or radiolucency in one or more zones.Conclusions: The early results of this modular femoral revision system are promising for the treatment of the deficient femur in complex primary and revision total hip arthroplasty. Patients with radiographic changes are advised to return for regular clinical and radiographic follow-up. Survival of the modular femoral component in this series was 100% at mean follow-up of 1.5 years and up to 3.7 years. While HHS clinical and pain scores were somewhat low at most recent evaluation, they were significantly improved over preoperative levels.
科研通智能强力驱动
Strongly Powered by AbleSci AI