Valiolah Ebrahimian,Farhad Namdari,Mahmoudreza Shakarami
标识
DOI:10.1080/15325008.2024.2305858
摘要
A non-linear autoregressive network with external inputs (NARX) model to reconstruct the current transformer (CT) secondary waveform distortion in the presence of protected transmission lines is presented. The qualitative analysis carried out on the autonomous model reveals the accurate performance of the current differential relay, because of the ability of the NARX to make accurate predictions and signal reconstruction even when faced with noisy or incomplete datasets. The suggested method uses samples of the line-protected remote current signal to produce a desired waveform. The unsaturated section is artificially expanded because it can estimate up to one sample after saturation with a respectable level of accuracy. The proposed method is evaluated by MATLAB and PSCAD software. The effectiveness of the suggested method for different fault types under varied situations has been proved. The simulation outcome confirms the method's high accuracy concerning the unusual system conditions in the presence of CT saturation.