重复性
组内相关
医学
变异系数
再现性
眼压
协议限制
氯胺酮
眼科
重复措施设计
平均差
水合氯醛
麻醉
核医学
数学
内科学
置信区间
统计
作者
Lifang Liu,Chukai Huang,Mingzhi Zhang
出处
期刊:DOAJ: Directory of Open Access Journals - DOAJ
日期:2014-01-01
卷期号:7 (6): 930-4
被引量:1
标识
DOI:10.3980/j.issn.2222-3959.2014.06.03
摘要
To assess the repeatability and reproducibility of Tonolab tonometer in rats with high intraocular pressure (IOP) and evaluate its ability to detect IOP changes in rats with general anaesthesia.Left eyes of adult Fischer rats (F344) were photocoagulated by 532 nm diode laser to induce high IOP. Hypertensive eyes of 30 conscious rats were randomly chosen to measure IOP on a single occasion. Two observers independently and alternately undertook IOP measurements consecutively for three times using the same Tonolab tonometer blind to the other observer's IOP measurements. The within subject standard deviation (Sw), coefficient of variation (CVw) (100×Sw/overall mean), and intraclass correlation coefficient (ICC) were calculated to evaluate intra-observer repeatability. Inter-observer difference was analysed by using 95% limits of agreement described by Bland-Altman and paired sample t-test. Also, another 13 normal F344 rats were intraperitoneally administrated with ketamine/xylazine or chloral hydrate, and IOPs of both eyes were measured by a single operator once every 5min until animals came to conscious. IOPs at various time points were compared by using one-way ANOVAs.Mean IOP was 35.58 mm Hg (range 17.33 to 65.33 mm Hg). For intraobserver repeatability, the Sw, CVw and ICC of high IOP for two observers were 5.20 mm Hg/3.41 mm Hg, 9.98%/8.08% and 0.820/0.928 respectively. The inter-observer difference was 14.76%±19.76% of the mean IOP of two observers, with a 95% limits of agreement -23.97% to 53.50%, and the difference between mean IOP of these two observers was statistically significant (P=0.001). IOPs dropped slightly during the first 15min post-aneathesia, with a IOP change between 0.17 and 1.17 mm Hg. IOPs changed from basline of 11.75±2.05 mm Hg (n=12) to 8.75±1.06 mm Hg 20min post-anesthesia (P=0.001), and this hypotensive condition persisted until 80min post-anesthesia.In this sample of hypertensive rats, Tonolab measurements demonstrated high levels of intraobserver repeatability, however, its interobserver reproducibility was poor. Longitudinal changes of IOP caused by genral anaesthesia can be sensitively detected by Tonolab. So we suggested that measurements of IOP using Tonolab are best measured by a single observer, and it could be included in experimental glaucoma.
科研通智能强力驱动
Strongly Powered by AbleSci AI