Improvement of sewage sludge dewatering by piezoelectric effect driven directly with pressure from pressure filtration: Towards understanding piezo-dewatering mechanism
Piezoelectric effect was firstly employed to improve dewatering efficiency of sludge. It was found that the piezoelectric effect could be driven directly by the pressure of pressure filtration process, without any additional energy. This piezo-dewatering process coupled piezoelectric effect with pressure filtration could efficiently remove moisture of sludge. Under 0.6 MPa for 2 h, moisture content (MC) and weight of sludge could be reduced to 63.9% and 3.2 g from 96.7% and 50 g by the piezo-dewatering process with 0.45 g t-BaTiO3. This piezo-dewatering efficiency was much higher than that of usual conditioning-pressure filtrations using CaO, FeCl3 or polyacrylamide (PAM) as the conditioners. And the piezo-dewatering process assisted by PAM could further decrease MC and weight of the sludge to 54.9% and 2.1 g, correspondingly, which complied to the advanced dewatering requirement (MC < 60%). The favorable piezo-dewatering efficiency was contributed to the piezo-catalytic oxidation and the electric role of remnant piezo-field. The finding of this piezo-dewatering mechanism offered an inspiring look at developing the emerging dewatering technology.