医学
呼吸窘迫
持续气道正压
呼吸系统
气道
重症监护医学
麻醉
内科学
阻塞性睡眠呼吸暂停
作者
George A. Gregory,Joseph A. Kitterman,Roderic H. Phibbs,William H. Tooley,William K. Hamilton
标识
DOI:10.1056/nejm197106172842401
摘要
Abstract We applied a continuous positive airway pressure to 20 infants (birth weight 930 to 3800 g) severely ill with the idiopathic respiratory-distress syndrome. They breathed spontaneously. Pressure, up to 12 mm of mercury, was delivered through an endotracheal tube to 18 infants and via a pressure chamber around the infant's head to two. Arterial oxygen tension rose in all, permitting us to lower the inspired oxygen an average of 37.5 per cent within 12 hours. Minute ventilation decreased with increased continuous positive airway pressure, but this had little effect on arterial carbon dioxide tension, pH, arterial blood pressure and lung compliance. Sixteen infants survived, including seven of 10 weighing less than 1500 g at birth.