DOI:10.23919/amtap.2017.8123695
摘要
Tilting the receive end wall of a compact range anechoic chamber to improve Radar Cross-Section (RCS) measurements has been a tool of the trade used since the earliest days of anechoic chambers. A preliminary analysis using geometrical optics (GO) validates this technique. The GO approach however ignores the backscattering modes from the reflected waves from a field of absorber. In this paper, a series of numerical experiments are performed comparing a straight wall and a tilted wall to show the effects on both the quiet zone and the energy reflected back towards the source antenna. Two Absorber covered walls are simulated. Both walls are illuminated with a standard gain horn (SGH). The effects of a wall tilted back 20° are computed. The simulations are done for 72-inch long absorber for the frequency range covering from 500 MHz to 1 GHz. The ripple on a 10 ft (3.05 m) quiet zone (QZ) is measured for the vertical wall and the tilted wall. In addition to the QZ analysis a time-domain analysis is performed. The reflected pulse at the excitation antenna is compared for the two back wall configurations Results show that tilting the wall improves measurements at some frequencies but causes a higher return at other frequencies; indicating this method does not provide a broadband advantage.