Accuracy of Intraocular Lens Power Calculation in Pediatric Secondary Implantation: In-the-Bag Versus Sulcus Placement

屈光度 人工晶状体 医学 眼科 外科 视力
作者
Zhenzhen Liu,Yingshi Zou,Yinglin Yu,Bo Qu,Ling Jin,Yuan Tan,Hui Chen,Jingmin Xu,Zhuoling Lin,Jing Li,Jianping Liu,Lixia Luo,Weirong Chen,Yizhi Liu
出处
期刊:American Journal of Ophthalmology [Elsevier BV]
卷期号:249: 137-143 被引量:2
标识
DOI:10.1016/j.ajo.2022.12.028
摘要

To compare the effects of secondary in-the-bag vs ciliary sulcus intraocular lens (IOL) implantation on the accuracy of IOL power calculation in pediatric eyes.Prospective nonrandomized interventional study.Pediatric aphakic eyes that underwent either in-the-bag or ciliary sulcus secondary IOL implantation were included. The mean prediction error (PE), mean absolute error (MAE), median absolute error, and percentages of eyes with PE within ±0.25 diopter (D), ±0.50 D, ±0.75 D, and ±1.00 D were calculated and compared using SRK/T formula.One hundred fourteen eyes (38.26%) received in-the-bag IOL implantation and 184 (61.74%) underwent ciliary sulcus IOL implantation. Compared with the sulcus group, the capsular group displayed significantly lower MAE and higher percentage of eyes within ±0.50 D of PE (MAE: 0.90 vs 1.56 D; ±0.50 D: 40.40% vs 14.29%, both P < .001). The eyes receiving in-the-bag IOL implantation (sulcus IOL implantation β: -1.060, 95% CI: -1.415 to -0.705; P < .001), unilateral (β: 0.647, 95% CI: 0.144-1.150; P = .012), or with deeper anterior chamber depth (β: 0.362, 95% CI: 0.068-0.656; P = .016) were prone to maintain hyperopia (PE > 0). To reduce PE, when the predicted capsular IOL power was between 11.50 and 30.00 D, the power of a sulcus-implanted IOL should be reduced by 0.50 to 2.50 D accordingly (the exact amount of reduction is positively related to the predicted power).In-the-bag implantation yielded smaller PE in pediatric eyes undergoing secondary IOL implantation. Adjustment of IOL power for ciliary sulcus implantation is required to reduce PE, and the amount of adjustment is positively correlated with the IOL power predicted by SRK/T formula.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
一顿要吃6碗饭完成签到,获得积分10
1秒前
星辰大海应助大胆的颜演采纳,获得10
1秒前
xu发布了新的文献求助10
1秒前
苏小慧发布了新的文献求助20
2秒前
爆米花应助shn采纳,获得10
2秒前
3秒前
3秒前
小二郎应助许飞采纳,获得10
3秒前
4秒前
飘逸的狗发布了新的文献求助30
5秒前
机灵柚子应助四季安采纳,获得20
5秒前
hv发布了新的文献求助30
8秒前
jj发布了新的文献求助10
8秒前
可爱的函函应助香蕉半邪采纳,获得10
9秒前
9秒前
9秒前
10秒前
11秒前
11秒前
Mia发布了新的文献求助10
12秒前
何大树完成签到,获得积分10
13秒前
orixero应助jj采纳,获得10
13秒前
在水一方应助芝意CHEAE采纳,获得10
13秒前
14秒前
范宇航完成签到 ,获得积分10
14秒前
小二郎应助xu采纳,获得10
14秒前
Fyf333发布了新的文献求助10
14秒前
罐装小姜发布了新的文献求助100
15秒前
SciGPT应助哈哈哈哈哈哈采纳,获得10
15秒前
16秒前
18秒前
健壮的诗槐完成签到,获得积分10
19秒前
干净的琦应助飘逸的狗采纳,获得30
20秒前
Akim应助风禾尽起采纳,获得10
20秒前
20秒前
21秒前
wt关闭了wt文献求助
21秒前
玉ER发布了新的文献求助10
21秒前
21秒前
22秒前
高分求助中
The Wiley Blackwell Companion to Diachronic and Historical Linguistics 3000
HANDBOOK OF CHEMISTRY AND PHYSICS 106th edition 1000
ASPEN Adult Nutrition Support Core Curriculum, Fourth Edition 1000
Signals, Systems, and Signal Processing 610
脑电大模型与情感脑机接口研究--郑伟龙 500
Genera Orchidacearum Volume 4: Epidendroideae, Part 1 500
GMP in Practice: Regulatory Expectations for the Pharmaceutical Industry 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 物理 内科学 复合材料 催化作用 物理化学 光电子学 电极 细胞生物学 基因 无机化学
热门帖子
关注 科研通微信公众号,转发送积分 6290313
求助须知:如何正确求助?哪些是违规求助? 8108563
关于积分的说明 16964452
捐赠科研通 5354668
什么是DOI,文献DOI怎么找? 2845419
邀请新用户注册赠送积分活动 1822582
关于科研通互助平台的介绍 1678319