医学
麻醉
气管插管
术前用药
喉罩气道
气道
插管
喉罩
作者
Amanda A. Wanous,Roland Brown,Kyle Rudser,Kari E. Roberts
标识
DOI:10.1038/s41372-023-01818-x
摘要
We hypothesize that the time, number of attempts, and physiologic stability of placement of an LMA would be superior compared to ETT. Videotape and physiologic parameters of LMA (n = 36) and ETT (n = 31) placement procedures for infants 28–36 weeks gestation were reviewed. Duration of attempts (32 vs 66 s, p < 0.001) and mean total airway insertion time (88 vs 153 s, p = 0.06) was shorter for LMA compared to ETT. Mean number of attempts for successful placement was fewer for LMA (1.5 vs 1.9, p = 0.11). Physiologic parameters remained near baseline in both groups despite very different degrees of premedication. Placement of an LMA required less time and fewer number of attempts compared to ETT. Physiologic stability of an LMA was maintained without the use of an analgesic and muscle relaxant. Use of an LMA is a favorable alternative to ETT placement for surfactant delivery in neonates. NCT01116921.
科研通智能强力驱动
Strongly Powered by AbleSci AI