作者
Aldridge Sd,Badellino Mm,Malaspina Pj,Milner Re,Roderic Warren,Comerota Aj,Buckman Rf
出处
期刊:PubMed
日期:1997-04-01
卷期号:38 (2): 183-6
摘要
To examine the extended patency (> 24 hrs) of heparin-bonded intravascular shunts in a porcine model of vascular injury.Adult swine underwent bilateral, common iliac artery resection (n = 5) or bilateral common iliac vein resection (n = 5) and vessel replacement with interposition, heparin-bonded shunts. Three control swine had vessel dissection only. Hematologic and coagulation profiles were measured at baseline and 24 hrs. Limb perfusion was assessed at 24 hrs by clinical exam and angiography.At 24 hrs, all limbs in both shunt groups were well perfused. All arterial shunts were angiographically patent. No distal emboli were detected. Nine of 10 venous shunts were patent, seven were lined with non-occluding thrombus. No alterations in hematologic or coagulation profiles were noted.Heparin-bonded shunts remained patent in arteries for 24 hours. Shunts placed in the venous system were prone to thrombus formation but most remained patent.