[Effect of different connection schemes of continuous renal replacement therapy and extracorporeal membrane oxygenation on arterial and venous pressure: an in vitro and in vivo study].

氧合器 体外膜肺氧合 膜式氧合器 导管 医学 肾脏替代疗法 充氧 麻醉 生物医学工程
作者
Jun Wang,Qiancheng Xu,Juan Li,Tao Wang,Changshun Zhong,Qun Chen,Ke Fang,Haijiao Jiang,Peng Zhang,Weihua Lu,Xiaogan Jiang
标识
DOI:10.3760/cma.j.cn121430-20210824-01261
摘要

To investigate the effects of different connection schemes of continuous renal replacement therapy (CRRT) and extracorporeal membrane oxygenation (ECMO) on arterial pressure (PA), venous pressure (PV), and transmembrane pressure (TMP), and to provide a theoretical basis for choosing a suitable connection scheme.(1) In vitro study: the different connection schemes of CRRT and ECMO were simulated and divided into 6 schemes according to the connection between CRRT and ECMO circuits at different positions. Scheme A: connected to the front and back points of the oxygenator; scheme B: connected to the points behind and in front of the oxygenator; scheme C: connected to the points in front of the oxygenator and in front of the centrifugal pump; scheme D: connected to the points behind the oxygenator and in front of the centrifugal pump; scheme E: connected to the points in front of the oxygenator and the return catheter; scheme F: connected to the points after the oxygenator and the return catheter. Each set of ECMO circuits was measured 5 times under each connection scheme and different flow rates (2, 3, 4, 5, 5.5 L/min). Six ECMO circuits for a total of 30 measurements, and the PA, PV, and TMP of the 6 schemes were compared. (2) In vivo study: the patients who were treated with ECMO combined with CRRT in the department of critical care medicine of the First Affiliated Hospital of Wannan Medical College from August 2017 to August 2021 changed the connection scheme due to high PA or PV (from scheme A or B to scheme E or F) were retrospectively analyzed. The changes of PA and PV before and after changing the scheme were compared.(1) In vitro study results: there was no significant difference in PA between schemes A and B, C and D, E and F under different ECMO blood flow (2-5.5 L/min). The PA of schemes C and D was the lowest, followed by schemes E and F. PV of scheme B was higher than that of scheme A under different ECMO blood flow (2-5.5 L/min). There was no significant difference in PV between schemes C and D, E and F under high ECMO blood flow (3-5.5 L/min), and the absolute value of PV was lowest in schemes E and F. Compared with schemes A and B [partial PA > 300 mmHg (1 mmHg ≈ 0.133 kPa) at high flow rate], C and D (partial PV > 350 mmHg at high flow rate), schemes E and F were more reasonable connection schemes. TMP was negative in schemes C and D at ECMO blood flow of 5 L/min and 5.5 L/min (mmHg; 5 L/min: scheme C was -29.14±11.42, scheme D was -42.45±15.70; 5.5 L/min: scheme C was -35.75±13.21, scheme D was -41.58±15.42), which indicated the presence of dialysate reverse filtration. Most of the differences in TMP among schemes A, B, E, and F under different ECMO blood flow (2-5.5 L/min) were statistically significant, and the absolute value of mean fluctuation was 9.89-49.55 mmHg, all within the normal range. (2) In vivo study results: a total of 10 patients who changed the connection scheme (from scheme A or B to E or F) due to high PA or PV were enrolled, including 8 males and 2 females; 7 cases of venous-arterial ECMO (VA-ECMO) and 3 cases of venous-venous ECMO (VV-ECMO), all used continuous veno-venous hemodiafiltration (CVVHDF) mode. After changing the scheme, both PA and PV decreased significantly as compared with those before changing [PA (mmHg): 244.00±22.58 vs. 257.20±21.92, PV (mmHg): 257.20±18.43 vs. 326.40±15.41, both P < 0.01], and PV decreased more significantly than PA [difference (mmHg): 69.20±6.55 vs. 13.20±5.45, P < 0.01].For patients treated with ECMO in combination with CRRT, the scheme of connecting the access line of CRRT to the pre-oxygenator or post-oxygenator and connecting the return line to the point of the return catheter can significantly reduce PA and PV and maintains normal CRRT operation even running high-flow ECMO.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
2秒前
鸿宇发布了新的文献求助10
3秒前
3秒前
衣裳薄完成签到,获得积分10
4秒前
星星泡饭完成签到,获得积分10
4秒前
5秒前
yyyy发布了新的文献求助10
5秒前
XJYXJY完成签到,获得积分10
5秒前
5秒前
5秒前
当当发布了新的文献求助10
6秒前
7秒前
LeiX发布了新的文献求助10
7秒前
8秒前
8秒前
柚子完成签到,获得积分20
9秒前
yhz_zjut_suda发布了新的文献求助10
10秒前
鸿宇完成签到,获得积分10
10秒前
Orange应助但但采纳,获得10
10秒前
10秒前
DE2022发布了新的文献求助10
11秒前
XJYXJY发布了新的文献求助30
11秒前
浮生完成签到,获得积分10
11秒前
皮代谷发布了新的文献求助10
11秒前
柚子发布了新的文献求助10
11秒前
11秒前
12秒前
13秒前
13秒前
14秒前
Hello应助yyyy采纳,获得10
14秒前
You发布了新的文献求助10
15秒前
汉堡包应助peace采纳,获得10
16秒前
17秒前
瞿冷完成签到 ,获得积分10
18秒前
成就初阳发布了新的文献求助10
18秒前
18秒前
Ssu完成签到,获得积分10
18秒前
asdfghjkl发布了新的文献求助10
19秒前
JamesPei应助DE2022采纳,获得10
20秒前
高分求助中
Continuum thermodynamics and material modelling 3000
Production Logging: Theoretical and Interpretive Elements 2700
Healthcare Finance: Modern Financial Analysis for Accelerating Biomedical Innovation 2000
Applications of Emerging Nanomaterials and Nanotechnology 1111
Unseen Mendieta: The Unpublished Works of Ana Mendieta 1000
Les Mantodea de Guyane Insecta, Polyneoptera 1000
工业结晶技术 880
热门求助领域 (近24小时)
化学 医学 材料科学 生物 工程类 有机化学 生物化学 纳米技术 内科学 物理 化学工程 计算机科学 复合材料 基因 遗传学 物理化学 催化作用 细胞生物学 免疫学 电极
热门帖子
关注 科研通微信公众号,转发送积分 3491062
求助须知:如何正确求助?哪些是违规求助? 3077779
关于积分的说明 9150152
捐赠科研通 2770160
什么是DOI,文献DOI怎么找? 1520088
邀请新用户注册赠送积分活动 704504
科研通“疑难数据库(出版商)”最低求助积分说明 702196