Accuracy of arthroscopic fluid pump systems in shoulder surgery: a comparison of 3 different pump systems

医学 关节镜检查 外科 外渗 压力传感器 麻醉 物理 免疫学 热力学
作者
Mohy E. Taha,K. Schneider,Margaret M. Smith,Grégory Cunningham,Allan Young,Benjamin Cass
出处
期刊:Journal of Shoulder and Elbow Surgery [Elsevier BV]
卷期号:29 (12): 2626-2631 被引量:6
标识
DOI:10.1016/j.jse.2020.03.039
摘要

Background Extra-articular fluid extravasation is a known complication during shoulder arthroscopy. The risk and amount of extravasation to a large degree is dependent on the fluid pressure delivered to the surgical site. Accurate measurement, knowledge, and control of the pressure delivered is thus important to surgeons, anesthetists, and the patient. The purpose of this study was to compare the pressure measurement accuracy of 3 arthroscopic fluid pumps, with 2 of them having 2 different settings. Methods Twenty-five patients (n = 5 per group) undergoing shoulder arthroscopy were selected. Three different arthroscopic fluid pumps (ConMed 24K, Stryker Crossflow, Arthrex Dual Wave) were tested in 5 different operational settings (Stryker, standard and dynamic mode; ConMed, with and without TIPS; Arthrex Dual Wave). In each operation, the set pump pressures and the subsequently delivered intra-articular surgical site fluid pressures were measured by a spinal needle connected to an anesthetic standard pressure transducer attached to the anesthetic machine. Independent measures of the surgical site pressures were obtained before multiple portals were created or extravasation had occurred. Measurements were taken at the beginning of surgery. Results Measurements of the mean intra-articular pressure were found to not be significantly different from the set pressure for the ConMed 24K with TIPS (0.98 ± 0.02-fold) and Stryker Crossflow in standard mode (0.98 ± 0.02-fold). However, actual pressure was significantly greater than the set pressure for the ConMed 24K without TIPS (by 1.30 ± 0.13-fold), Stryker Crossflow in dynamic mode (by 1.82 ± 0.08-fold), and Arthrex Dual Wave (by 2.19 ± 0.06-fold). Conclusion Independently measured intra-articular pressure can be more than double the set pressure for some arthroscopic pumps. Measuring intra-articular pressure can thus aid in adjusting the set pressure. This could minimize the risk of intraoperative complications. Extra-articular fluid extravasation is a known complication during shoulder arthroscopy. The risk and amount of extravasation to a large degree is dependent on the fluid pressure delivered to the surgical site. Accurate measurement, knowledge, and control of the pressure delivered is thus important to surgeons, anesthetists, and the patient. The purpose of this study was to compare the pressure measurement accuracy of 3 arthroscopic fluid pumps, with 2 of them having 2 different settings. Twenty-five patients (n = 5 per group) undergoing shoulder arthroscopy were selected. Three different arthroscopic fluid pumps (ConMed 24K, Stryker Crossflow, Arthrex Dual Wave) were tested in 5 different operational settings (Stryker, standard and dynamic mode; ConMed, with and without TIPS; Arthrex Dual Wave). In each operation, the set pump pressures and the subsequently delivered intra-articular surgical site fluid pressures were measured by a spinal needle connected to an anesthetic standard pressure transducer attached to the anesthetic machine. Independent measures of the surgical site pressures were obtained before multiple portals were created or extravasation had occurred. Measurements were taken at the beginning of surgery. Measurements of the mean intra-articular pressure were found to not be significantly different from the set pressure for the ConMed 24K with TIPS (0.98 ± 0.02-fold) and Stryker Crossflow in standard mode (0.98 ± 0.02-fold). However, actual pressure was significantly greater than the set pressure for the ConMed 24K without TIPS (by 1.30 ± 0.13-fold), Stryker Crossflow in dynamic mode (by 1.82 ± 0.08-fold), and Arthrex Dual Wave (by 2.19 ± 0.06-fold). Independently measured intra-articular pressure can be more than double the set pressure for some arthroscopic pumps. Measuring intra-articular pressure can thus aid in adjusting the set pressure. This could minimize the risk of intraoperative complications.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
6秒前
L1发布了新的文献求助10
11秒前
领导范儿应助lian采纳,获得10
24秒前
科研通AI2S应助科研通管家采纳,获得10
26秒前
43秒前
lian发布了新的文献求助10
48秒前
1分钟前
乐乐应助lian采纳,获得10
1分钟前
1分钟前
lian发布了新的文献求助10
1分钟前
mieyy完成签到,获得积分10
1分钟前
2分钟前
Zoe发布了新的文献求助10
2分钟前
酷波er应助Zoe采纳,获得10
2分钟前
苹果松完成签到 ,获得积分20
2分钟前
麻麻薯完成签到 ,获得积分10
2分钟前
顾矜应助lian采纳,获得10
2分钟前
2分钟前
2分钟前
3分钟前
lian发布了新的文献求助10
3分钟前
tfonda完成签到 ,获得积分10
3分钟前
自由的云朵完成签到 ,获得积分10
3分钟前
lian发布了新的文献求助10
3分钟前
顾矜应助一彤采纳,获得10
3分钟前
3分钟前
4分钟前
Zoe发布了新的文献求助10
4分钟前
无花果应助lian采纳,获得10
4分钟前
科研通AI2S应助科研通管家采纳,获得10
4分钟前
4分钟前
lian发布了新的文献求助10
4分钟前
4分钟前
5分钟前
一彤发布了新的文献求助10
5分钟前
5分钟前
领导范儿应助lian采纳,获得10
5分钟前
传奇3应助Zoe采纳,获得10
5分钟前
默默无闻完成签到 ,获得积分10
5分钟前
6分钟前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Chemistry and Physics of Carbon Volume 18 800
The Organometallic Chemistry of the Transition Metals 800
The formation of Australian attitudes towards China, 1918-1941 640
Signals, Systems, and Signal Processing 610
天津市智库成果选编 600
全相对论原子结构与含时波包动力学的理论研究--清华大学 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 物理 内科学 复合材料 催化作用 物理化学 光电子学 电极 细胞生物学 基因 无机化学
热门帖子
关注 科研通微信公众号,转发送积分 6444591
求助须知:如何正确求助?哪些是违规求助? 8258492
关于积分的说明 17591155
捐赠科研通 5503940
什么是DOI,文献DOI怎么找? 2901474
邀请新用户注册赠送积分活动 1878492
关于科研通互助平台的介绍 1717870