Advanced glycation end products (AGEs) and heterocyclic amines (HAs) are main harmful Maillard reaction products of meat products. Simultaneous quantification of both with high sensitivity, selectivity and accuracy remains a major challenge due to inconsistencies in their pre-treatment and instrumental methods and the different polarity of AGEs and HAs. We developed a method for the simultaneous determination of AGEs and HAs in roast/grilled meat by ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) using dynamic multiple reaction monitoring (D-MRM). The instrument parameters and pre-treatment method were optimized to achieve reasonably good separation and high response for the 11 target analytes within 8 min. From 10 to 200 ng/mL, the limits of detection (LODs) and limits of quantitation (LOQs) ranged from 0.3 to 5.5 μg/L and 0.9 to 6.3 μg/L, respectively, and the correlation coefficient (R2) was >0.99. It was acceptable to recoveries, standard deviations (RSDs), and matrix effects. Six types of roast/grilled meat samples were then tested using the developed method.