精子
人类受精
DNA断裂
男科
精液
人口
精子活力
生物
精液质量
医学
遗传学
细胞凋亡
程序性细胞死亡
环境卫生
作者
Nadia Sheibak,Fatemehsadat Amjadi,Amir Shamloo,Fatemeh Zarei,Zahra Zandieh
出处
期刊:Human Reproduction
[Oxford University Press]
日期:2024-03-10
卷期号:39 (5): 902-911
被引量:2
标识
DOI:10.1093/humrep/deae045
摘要
Abstract STUDY QUESTION Is a microfluidic sperm sorter (MSS) able to select higher quality sperm compared to conventional methods? SUMMARY ANSWER The MSS selects sperm with improved parameters, lower DNA fragmentation, and higher fertilizing potential. WHAT IS KNOWN ALREADY To date, the few studies that have compared microfluidics sperm selection with conventional methods have used heterogeneous study population and have lacked molecular investigations. STUDY DESIGN, SIZE, DURATION The efficiency of a newly designed MSS in isolating high-quality sperm was compared to the density-gradient centrifugation (DGC) and swim-up (SU) methods, using 100 semen samples in two groups, during 2023–2024. PARTICIPANTS/MATERIALS, SETTING, METHODS Semen specimens from 50 normozoospermic and 50 non-normozoospermic men were sorted using MSS, DGC, and SU methods to compare parameters related to the quality and fertilizing potential of sperm. The fertilizing potential of sperm was determined by measurement of phospholipase C zeta (PLCζ) and post-acrosomal sheath WW domain-binding protein (PAWP) expression using flow cytometry, and the chromatin dispersion test was used to assess sperm DNA damage. MAIN RESULTS AND THE ROLE OF CHANCE In both normozoospermic and non-normozoospermic groups, the MSS-selected sperm with the highest progressive motility, PLCζ positive expression and PLCζ and PAWP fluorescence intensity the lowest non-progressive motility, and minimal DNA fragmentation, compared to sperm selected by DGC and SU methods (P < 0.05). LIMITATION, REASONS FOR CAUTION The major limitations of our study were the low yield of sperm in the MSS chips and intentional exclusion of severe male factor infertility to yield a sufficient sperm count for molecular experiments; thus testing with severe oligozoospermic semen and samples with low count and motility is still required. In addition, due to ethical considerations, at present, it was impossible to use the sperm achieved from MSS in the clinic to assess the fertilization rate and further outcomes. WIDER IMPLICATIONS OF THE FINDINGS Our research presents new evidence that microfluidic sperm sorting may result in the selection of high-quality sperm from raw semen. This novel technology might be a key to improving clinical outcomes of assisted reproduction in infertile patients. STUDY FUNDING/COMPETING INTEREST(S) The study is funded by the Iran University of Medical Sciences and no competing interest exists. TRIAL REGISTRATION NUMBER N/A.
科研通智能强力驱动
Strongly Powered by AbleSci AI