医学
穿孔
吻合
支架
外科
泄漏
食管支架
食管狭窄
食管
环境工程
工程类
冶金
材料科学
冲孔
作者
Bobby Dasari,David Neely,Kennedy Andrew,Gary Spence,Paul Rice,E. J. Mackle,E Epanomeritakis
出处
期刊:Annals of Surgery
[Ovid Technologies (Wolters Kluwer)]
日期:2014-05-01
卷期号:259 (5): 852-860
被引量:217
标识
DOI:10.1097/sla.0000000000000564
摘要
In Brief Objective: The aim of this review was to assess the safety and effectiveness of esophageal stents in the management of benign esophageal perforation and in the management of esophageal anastomotic leaks. Background: Benign esophageal perforation and postoperative esophageal anastomotic leak are often encountered. Endoscopic placement of esophageal stent across the site of leakage might help control the sepsis and reduce the mortality and morbidity. Methods: All the published case series reporting the use of metallic and plastic stents in the management of postoperative anastomotic leaks, spontaneous esophageal perforations, and iatrogenic esophageal perforations were identified from MEDLINE, EMBASE, and PubMed (1990-2012). Primary outcomes assessed were technical success rates and complete healing rates. Secondary outcomes assessed were stent migration rates, stent perforation rates, duration of hospital stay, time to stent removal, and mortality rates. A pooled analysis was performed and subgroup analysis was performed for plastic versus metallic stents and anastomotic leaks versus perforations separately. Results: A total of 27 case series with 340 patients were included. Technical and clinical success rates of stenting were 91% and 81%, respectively. Stent migration rates were significantly higher with plastic stents than with metallic stents (40/148 vs 13/117 patients, respectively; P = 0.001). Patients with metallic stents had significantly higher incidence of postprocedure strictures (P = 0.006). However, patients with plastic stents needed significantly higher number of reinterventions (P = 0.005). Mean postprocedure hospital stay varied from 8 days to 51 days. There was no significant difference in the primary or secondary outcomes when stenting was performed for anastomotic leaks or perforations. Conclusions: Endoscopic management of esophageal anastomotic leaks and perforations with the use of esophageal stents is technically feasible. It seems to be safe and effective when performed along with mediastinal or pleural drainage. Esophageal stent can, therefore, be considered as a treatment option in the management of patients who present early after esophageal perforation or anastomotic leak with limited mediastinal or pleural contamination. Endoscopic management of esophageal anastomotic leaks and perforations with the use of esophageal stents is technically feasible. It seems to be safe and effective when performed along with mediastinal or pleural drainage in patients with limited mediastinal or pleural contamination.
科研通智能强力驱动
Strongly Powered by AbleSci AI