医学
肺癌
淋巴
病理
荧光寿命成像显微镜
手术切缘
癌症
免疫组织化学
肺
体内
离体
放射科
荧光
内科学
生物
物理
量子力学
生物技术
作者
Changjian Li,Jiahui Mi,Yueqi Wang,Zeyu Zhang,Xiaoyong Guo,Jian Zhou,Zhenhua Hu,Jie Tian
标识
DOI:10.1007/s00259-022-05975-7
摘要
During lung cancer surgery, it is very important to define tumor boundaries and determine the surgical margin distance. In previous research, systemically application of fluorescent probes can help medical professionals determine the boundaries of tumors and find small tumors and metastases, thereby improving the accuracy of surgical resection. However, there are very few safe and effective probes that can be applied to clinical trials up to now, which limits the clinical application of fluorescence imaging. Here we developed a new technology that can quickly identify the tumor area in the resected lung tissue during the operation and distinguish the tumor boundary and metastatic lymph nodes.For animal studies, a PDX model of lung cancer was established. The tumors, lungs, and peritumoral muscle tissues of tumor-bearing mice were surgically removed and incubated with a probe targeting epidermal growth factor receptor (EGFR) for 20 min, and then imaged by a closed-field near-infrared two-zone (NIR-II) fluorescence imaging system. For clinical samples, ten surgically removed lung tissues and 60 lymph nodes from 10 lung cancer patients undergoing radical resection were incubated with the targeting probe immediately after intraoperative resection and imaged to identify the tumor area and distinguish the tumor boundary and metastatic lymph nodes. The accuracy of fluorescence imaging was confirmed by HE staining and immunohistochemistry.The ex vivo animal imaging experiments showed a fluorescence enhancement of tumor tissue. For clinical samples, our results showed that this new technology yielded more than 85.7% sensitivity and 100% specificity in identifying the tumor area in the resected lung tissue. The average fluorescence tumor-to-background ratio was 2.5 ± 1.3. Furthermore, we also used this technique to image metastatic lymph nodes intraoperatively and showed that metastatic lymph nodes have brighter fluorescence than normal lymph nodes, as the average fluorescence tumor-to-background signal ratio was 2.7 ± 1.1. Calculations on the results of the fluorescence signal in relation to the number of metastatic lymph nodes yielded values of 77.8% for sensitivity and 92.1% for specificity. We expect this new technology to be a useful diagnostic tool for rapid intraoperative pathological detection and margin determination.By using fluorescently labeled anti-human EGFR recombinant antibody scFv fragment to incubate freshly isolated tissues during surgery, the probes can quickly accumulate in lung cancer tissues, which can be used to quickly identify tumor areas in the resected lung tissues and distinguish tumor boundaries and find metastases in lymph nodes. This technology is expected to be used for rapid intraoperative pathological detection and margin determination.
科研通智能强力驱动
Strongly Powered by AbleSci AI