S9 Adverse Events and Device Failures Associated With Pancreatic Stents: A Comprehensive Analysis Using the FDA's MAUDE Database

医学 不利影响 穿孔 胰腺炎 不良事件报告系统 数据库 食品药品监督管理局 内镜治疗 胰管 急诊医学 内科学 外科 内窥镜检查 医疗急救 材料科学 冶金 冲孔 计算机科学
作者
Fouad Jaber,Saqr Alsakarneh,Mohammad Jaber,Khalid K. Ahmed,Azizullah Beran,Khaled Elfert,Ahmed Salih,Manasik Abdu,Yazan Abboud,Zubair Khan,Mohamed Ismail,Joseph Sleiman,Mohamed Abdallah,Ala Abdel-Jalil,Mohammad Bilal
出处
期刊:The American Journal of Gastroenterology [American College of Gastroenterology]
卷期号:118 (10S): S8-S9
标识
DOI:10.14309/01.ajg.0000949676.28499.48
摘要

Introduction: Pancreatic duct stents (PDS) are widely used for the prevention of post-ERCP pancreatitis and for pancreatic endotherapy in chronic pancreatitis patients. Several commercially available PDS are commonly utilized. However, there is a paucity of data regarding the adverse events associated with PDS placement. This study aims to investigate the reported adverse events and device failures related to PDS, utilizing the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA). Methods: Post-marketing surveillance data from January 2010 to May 2023 were extracted from the FDA's MAUDE database to analyze the outcomes associated with PDS. Reports pertaining to the use of commonly used PDS including Advanix (Boston Scientfic), Geenan (Cook endoscopy), and Zimmon (Cook endoscopy) pancreatic stents were analyzed. The primary outcomes of interest were device problems and patient-related adverse events. Statistical analysis was performed using Microsoft Excel 2010, with calculation of pooled numbers and percentages for each device and patient adverse event. Results: During the study period, a total of 540 device problems and 582 patient-related adverse events were identified. Device failures (Figure 1) were primarily attributed to device or usage problems (n=145, 26.9%), followed by off-label use (n=144, 26.7%), and material or component issues (n=120, 22.2%). The most common patient-related adverse events were reported as having no harm or consequences to patients (n=400, 68.7%). Other reported patient adverse events included inflammation (n=24, 4.1%), perforation (n=16, 2.7%), foreign body presence (n=14, 2.4%), and pancreatitis (n=10, 1.7%). The highest number of device failures was associated with Zimmon pancreatic stents (n=217, 40.2%), followed by Geenen pancreatic stents (n=216, 40%) and Advanix (n=107, 19.8%). Device or usage problems were most frequently reported with the use of Zimmon stents (n=79, 36.4%), followed by Geenen stents (n=60, 27.8%). Conclusion: Most reported device-related issues were attributed to device or usage problems, and the majority of device failures did not result in harm to patients. Information from this study can be used in improving pancreatic duct stent designs for future iterations.Figure 1.: A) Device Failures associated with pancreatic stents. B) Patient-related adverse Events associated with pancreatic stents. Device or Use Problems (Adverse Event Without Identified Device or Use Problem, no apparent adverse events, Use of Device Problem, Improper or Incorrect Procedure or Method, Device Operates Differently Than Expected), Activation, Positioning or Separation Problem (Activation Failure, Activation, Difficult or Delayed Positioning, Positioning or Separation Problem, Positioning Failure, Positioning Problem), Material or Component Problems (Break, Material Deformation, Material Integrity Problem, Material Puncture/Hole, defective device, component failing, fracture), Device Markings or Packaging Problems (Device Markings/Labelling Problem, Device Packaging), Difficulties with Device (Difficult to Advance, Difficult to Remove, Device Difficult to Setup or Prepare, failure to advance), Migration (Migration or Expulsion of Device, Migration, Detachment of Device or Device Component), Sterilization (Problem with sterilization, Contamination /Decontamination Problem), Others (Entrapment of Device, Retraction Problem; Stretched, off label use, biocompatibility, fluid/blood leakage, appropriate code not available, insufficient information, obstruction of flow, leak/splash) Pain related (Abdominal pain/pain/implant pain), Bleeding-related (Bleeding/hemorrhage, blood).

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
abc发布了新的文献求助10
3秒前
6秒前
情怀应助我又不会后仰采纳,获得30
7秒前
duola123完成签到 ,获得积分10
9秒前
CH3OH发布了新的文献求助10
12秒前
六元一斤虾完成签到 ,获得积分10
17秒前
脑洞疼应助CH3OH采纳,获得30
18秒前
20秒前
小布发布了新的文献求助10
24秒前
浮浮世世发布了新的文献求助10
24秒前
李大刚完成签到 ,获得积分10
27秒前
CH3OH完成签到,获得积分10
32秒前
满意的匪完成签到 ,获得积分10
33秒前
joysa完成签到,获得积分10
33秒前
丸子完成签到 ,获得积分10
36秒前
36秒前
yangzai完成签到 ,获得积分0
41秒前
灵巧的蓝发布了新的文献求助10
41秒前
Ttttt发布了新的文献求助10
44秒前
44秒前
2589完成签到,获得积分10
49秒前
51秒前
Akim应助灵巧的蓝采纳,获得10
52秒前
55秒前
Lifel完成签到 ,获得积分10
55秒前
我又不会后仰完成签到,获得积分10
56秒前
57秒前
AZN关闭了AZN文献求助
58秒前
杨柳9203完成签到,获得积分10
58秒前
1分钟前
科研通AI2S应助科研通管家采纳,获得10
1分钟前
打打应助科研通管家采纳,获得10
1分钟前
1分钟前
思源应助qinglongtsmc采纳,获得10
1分钟前
科目三应助abc采纳,获得10
1分钟前
1分钟前
Akim应助hy993采纳,获得10
1分钟前
qinglongtsmc发布了新的文献求助10
1分钟前
优美紫槐应助耍酷的海秋采纳,获得10
1分钟前
朱向阳完成签到 ,获得积分10
1分钟前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
人脑智能与人工智能 1000
理系総合のための生命科学 第5版〜分子・細胞・個体から知る“生命"のしくみ 800
普遍生物学: 物理に宿る生命、生命の紡ぐ物理 800
花の香りの秘密―遺伝子情報から機能性まで 800
King Tyrant 720
Silicon in Organic, Organometallic, and Polymer Chemistry 500
热门求助领域 (近24小时)
化学 材料科学 生物 医学 工程类 计算机科学 有机化学 物理 生物化学 纳米技术 复合材料 内科学 化学工程 人工智能 催化作用 遗传学 数学 基因 量子力学 物理化学
热门帖子
关注 科研通微信公众号,转发送积分 5606518
求助须知:如何正确求助?哪些是违规求助? 4690912
关于积分的说明 14866566
捐赠科研通 4706287
什么是DOI,文献DOI怎么找? 2542732
邀请新用户注册赠送积分活动 1508144
关于科研通互助平台的介绍 1472276