S9 Adverse Events and Device Failures Associated With Pancreatic Stents: A Comprehensive Analysis Using the FDA's MAUDE Database

医学 不利影响 穿孔 胰腺炎 不良事件报告系统 数据库 食品药品监督管理局 内镜治疗 胰管 急诊医学 内科学 外科 内窥镜检查 医疗急救 材料科学 计算机科学 冲孔 冶金
作者
Fouad Jaber,Saqr Alsakarneh,Mohammad Jaber,Khalid K. Ahmed,Azizullah Beran,Khaled Elfert,Ahmed Salih,Manasik Abdu,Yazan Abboud,Zubair Khan,Mohamed Ismail,Joseph Sleiman,Mohamed Abdallah,Ala Abdel-Jalil,Mohammad Bilal
出处
期刊:The American Journal of Gastroenterology [American College of Gastroenterology]
卷期号:118 (10S): S8-S9
标识
DOI:10.14309/01.ajg.0000949676.28499.48
摘要

Introduction: Pancreatic duct stents (PDS) are widely used for the prevention of post-ERCP pancreatitis and for pancreatic endotherapy in chronic pancreatitis patients. Several commercially available PDS are commonly utilized. However, there is a paucity of data regarding the adverse events associated with PDS placement. This study aims to investigate the reported adverse events and device failures related to PDS, utilizing the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA). Methods: Post-marketing surveillance data from January 2010 to May 2023 were extracted from the FDA's MAUDE database to analyze the outcomes associated with PDS. Reports pertaining to the use of commonly used PDS including Advanix (Boston Scientfic), Geenan (Cook endoscopy), and Zimmon (Cook endoscopy) pancreatic stents were analyzed. The primary outcomes of interest were device problems and patient-related adverse events. Statistical analysis was performed using Microsoft Excel 2010, with calculation of pooled numbers and percentages for each device and patient adverse event. Results: During the study period, a total of 540 device problems and 582 patient-related adverse events were identified. Device failures (Figure 1) were primarily attributed to device or usage problems (n=145, 26.9%), followed by off-label use (n=144, 26.7%), and material or component issues (n=120, 22.2%). The most common patient-related adverse events were reported as having no harm or consequences to patients (n=400, 68.7%). Other reported patient adverse events included inflammation (n=24, 4.1%), perforation (n=16, 2.7%), foreign body presence (n=14, 2.4%), and pancreatitis (n=10, 1.7%). The highest number of device failures was associated with Zimmon pancreatic stents (n=217, 40.2%), followed by Geenen pancreatic stents (n=216, 40%) and Advanix (n=107, 19.8%). Device or usage problems were most frequently reported with the use of Zimmon stents (n=79, 36.4%), followed by Geenen stents (n=60, 27.8%). Conclusion: Most reported device-related issues were attributed to device or usage problems, and the majority of device failures did not result in harm to patients. Information from this study can be used in improving pancreatic duct stent designs for future iterations.Figure 1.: A) Device Failures associated with pancreatic stents. B) Patient-related adverse Events associated with pancreatic stents. Device or Use Problems (Adverse Event Without Identified Device or Use Problem, no apparent adverse events, Use of Device Problem, Improper or Incorrect Procedure or Method, Device Operates Differently Than Expected), Activation, Positioning or Separation Problem (Activation Failure, Activation, Difficult or Delayed Positioning, Positioning or Separation Problem, Positioning Failure, Positioning Problem), Material or Component Problems (Break, Material Deformation, Material Integrity Problem, Material Puncture/Hole, defective device, component failing, fracture), Device Markings or Packaging Problems (Device Markings/Labelling Problem, Device Packaging), Difficulties with Device (Difficult to Advance, Difficult to Remove, Device Difficult to Setup or Prepare, failure to advance), Migration (Migration or Expulsion of Device, Migration, Detachment of Device or Device Component), Sterilization (Problem with sterilization, Contamination /Decontamination Problem), Others (Entrapment of Device, Retraction Problem; Stretched, off label use, biocompatibility, fluid/blood leakage, appropriate code not available, insufficient information, obstruction of flow, leak/splash) Pain related (Abdominal pain/pain/implant pain), Bleeding-related (Bleeding/hemorrhage, blood).
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
Verdigris完成签到,获得积分10
1秒前
cindy完成签到,获得积分10
1秒前
研友_VZG7GZ应助愉快彩虹采纳,获得10
1秒前
金色热浪完成签到 ,获得积分10
1秒前
快去读文献完成签到,获得积分20
1秒前
斯文静曼完成签到,获得积分10
1秒前
1秒前
1秒前
拼搏思卉关注了科研通微信公众号
2秒前
2秒前
liudiqiu应助酷酷的起眸采纳,获得10
2秒前
研友_8yN60L发布了新的文献求助10
2秒前
所所应助VDC采纳,获得10
2秒前
xxq发布了新的文献求助30
2秒前
xzy发布了新的文献求助20
3秒前
Linanana完成签到,获得积分10
3秒前
3秒前
贾舒涵发布了新的文献求助10
3秒前
Sunrise完成签到,获得积分10
4秒前
HH完成签到,获得积分10
5秒前
科研通AI2S应助飞羽采纳,获得10
5秒前
风中寄云完成签到,获得积分20
5秒前
故意的傲玉应助毛慢慢采纳,获得10
5秒前
5秒前
小白发布了新的文献求助10
5秒前
6秒前
6秒前
马尼拉发布了新的文献求助10
7秒前
CodeCraft应助dildil采纳,获得10
7秒前
7秒前
cyanpomelo完成签到 ,获得积分10
8秒前
8秒前
微笑高山完成签到 ,获得积分10
8秒前
文献查找发布了新的文献求助10
8秒前
加油完成签到,获得积分20
9秒前
Sunrise发布了新的文献求助10
9秒前
tabor发布了新的文献求助10
9秒前
唐妮完成签到,获得积分10
9秒前
啵清啵完成签到,获得积分10
10秒前
10秒前
高分求助中
Continuum Thermodynamics and Material Modelling 3000
Production Logging: Theoretical and Interpretive Elements 2700
Social media impact on athlete mental health: #RealityCheck 1020
Ensartinib (Ensacove) for Non-Small Cell Lung Cancer 1000
Unseen Mendieta: The Unpublished Works of Ana Mendieta 1000
Bacterial collagenases and their clinical applications 800
El viaje de una vida: Memorias de María Lecea 800
热门求助领域 (近24小时)
化学 材料科学 生物 医学 工程类 有机化学 生物化学 物理 纳米技术 计算机科学 内科学 化学工程 复合材料 基因 遗传学 物理化学 催化作用 量子力学 光电子学 冶金
热门帖子
关注 科研通微信公众号,转发送积分 3527699
求助须知:如何正确求助?哪些是违规求助? 3107752
关于积分的说明 9286499
捐赠科研通 2805513
什么是DOI,文献DOI怎么找? 1539954
邀请新用户注册赠送积分活动 716878
科研通“疑难数据库(出版商)”最低求助积分说明 709759