S9 Adverse Events and Device Failures Associated With Pancreatic Stents: A Comprehensive Analysis Using the FDA's MAUDE Database

医学 不利影响 穿孔 胰腺炎 不良事件报告系统 数据库 食品药品监督管理局 内镜治疗 胰管 急诊医学 内科学 外科 内窥镜检查 医疗急救 材料科学 冶金 冲孔 计算机科学
作者
Fouad Jaber,Saqr Alsakarneh,Mohammad Jaber,Khalid K. Ahmed,Azizullah Beran,Khaled Elfert,Ahmed Salih,Manasik Abdu,Yazan Abboud,Zubair Khan,Mohamed Ismail,Joseph Sleiman,Mohamed Abdallah,Ala Abdel-Jalil,Mohammad Bilal
出处
期刊:The American Journal of Gastroenterology [American College of Gastroenterology]
卷期号:118 (10S): S8-S9
标识
DOI:10.14309/01.ajg.0000949676.28499.48
摘要

Introduction: Pancreatic duct stents (PDS) are widely used for the prevention of post-ERCP pancreatitis and for pancreatic endotherapy in chronic pancreatitis patients. Several commercially available PDS are commonly utilized. However, there is a paucity of data regarding the adverse events associated with PDS placement. This study aims to investigate the reported adverse events and device failures related to PDS, utilizing the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA). Methods: Post-marketing surveillance data from January 2010 to May 2023 were extracted from the FDA's MAUDE database to analyze the outcomes associated with PDS. Reports pertaining to the use of commonly used PDS including Advanix (Boston Scientfic), Geenan (Cook endoscopy), and Zimmon (Cook endoscopy) pancreatic stents were analyzed. The primary outcomes of interest were device problems and patient-related adverse events. Statistical analysis was performed using Microsoft Excel 2010, with calculation of pooled numbers and percentages for each device and patient adverse event. Results: During the study period, a total of 540 device problems and 582 patient-related adverse events were identified. Device failures (Figure 1) were primarily attributed to device or usage problems (n=145, 26.9%), followed by off-label use (n=144, 26.7%), and material or component issues (n=120, 22.2%). The most common patient-related adverse events were reported as having no harm or consequences to patients (n=400, 68.7%). Other reported patient adverse events included inflammation (n=24, 4.1%), perforation (n=16, 2.7%), foreign body presence (n=14, 2.4%), and pancreatitis (n=10, 1.7%). The highest number of device failures was associated with Zimmon pancreatic stents (n=217, 40.2%), followed by Geenen pancreatic stents (n=216, 40%) and Advanix (n=107, 19.8%). Device or usage problems were most frequently reported with the use of Zimmon stents (n=79, 36.4%), followed by Geenen stents (n=60, 27.8%). Conclusion: Most reported device-related issues were attributed to device or usage problems, and the majority of device failures did not result in harm to patients. Information from this study can be used in improving pancreatic duct stent designs for future iterations.Figure 1.: A) Device Failures associated with pancreatic stents. B) Patient-related adverse Events associated with pancreatic stents. Device or Use Problems (Adverse Event Without Identified Device or Use Problem, no apparent adverse events, Use of Device Problem, Improper or Incorrect Procedure or Method, Device Operates Differently Than Expected), Activation, Positioning or Separation Problem (Activation Failure, Activation, Difficult or Delayed Positioning, Positioning or Separation Problem, Positioning Failure, Positioning Problem), Material or Component Problems (Break, Material Deformation, Material Integrity Problem, Material Puncture/Hole, defective device, component failing, fracture), Device Markings or Packaging Problems (Device Markings/Labelling Problem, Device Packaging), Difficulties with Device (Difficult to Advance, Difficult to Remove, Device Difficult to Setup or Prepare, failure to advance), Migration (Migration or Expulsion of Device, Migration, Detachment of Device or Device Component), Sterilization (Problem with sterilization, Contamination /Decontamination Problem), Others (Entrapment of Device, Retraction Problem; Stretched, off label use, biocompatibility, fluid/blood leakage, appropriate code not available, insufficient information, obstruction of flow, leak/splash) Pain related (Abdominal pain/pain/implant pain), Bleeding-related (Bleeding/hemorrhage, blood).

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
ljh发布了新的文献求助10
刚刚
吴裙裙完成签到,获得积分20
刚刚
1秒前
1秒前
蓝天应助awaer采纳,获得10
2秒前
蓝天应助东方傲儿采纳,获得10
2秒前
灵巧冰露发布了新的文献求助10
2秒前
852应助明理念桃采纳,获得10
2秒前
2秒前
2秒前
3秒前
蓝天应助生命化育采纳,获得10
3秒前
3秒前
青山见我发布了新的文献求助10
3秒前
cfv发布了新的文献求助10
3秒前
大气映冬完成签到,获得积分10
4秒前
4秒前
Criminology34应助无zzz的人采纳,获得10
4秒前
烟花应助yz采纳,获得10
5秒前
5秒前
通通通发布了新的文献求助30
5秒前
5秒前
6秒前
贾哲宇完成签到,获得积分10
6秒前
6秒前
6秒前
量子星尘发布了新的文献求助10
7秒前
小猪找库里完成签到,获得积分10
7秒前
月月月鸟伟完成签到,获得积分10
7秒前
慕青应助kkeeaa采纳,获得10
7秒前
8秒前
zsqqqqq发布了新的文献求助10
8秒前
个性的紫菜应助上善若水采纳,获得10
8秒前
Ashore发布了新的文献求助10
8秒前
8秒前
俊逸的念桃完成签到,获得积分10
8秒前
9秒前
9秒前
9秒前
9秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Encyclopedia of Quaternary Science Reference Third edition 6000
Encyclopedia of Forensic and Legal Medicine Third Edition 5000
Introduction to strong mixing conditions volume 1-3 5000
Aerospace Engineering Education During the First Century of Flight 3000
Agyptische Geschichte der 21.30. Dynastie 3000
Les Mantodea de guyane 2000
热门求助领域 (近24小时)
化学 材料科学 生物 医学 工程类 计算机科学 有机化学 物理 生物化学 纳米技术 复合材料 内科学 化学工程 人工智能 催化作用 遗传学 数学 基因 量子力学 物理化学
热门帖子
关注 科研通微信公众号,转发送积分 5784558
求助须知:如何正确求助?哪些是违规求助? 5682922
关于积分的说明 15464566
捐赠科研通 4913664
什么是DOI,文献DOI怎么找? 2644848
邀请新用户注册赠送积分活动 1592770
关于科研通互助平台的介绍 1547187