S9 Adverse Events and Device Failures Associated With Pancreatic Stents: A Comprehensive Analysis Using the FDA's MAUDE Database

医学 不利影响 穿孔 胰腺炎 不良事件报告系统 数据库 食品药品监督管理局 内镜治疗 胰管 急诊医学 内科学 外科 内窥镜检查 医疗急救 材料科学 计算机科学 冲孔 冶金
作者
Fouad Jaber,Saqr Alsakarneh,Mohammad Jaber,Khalid K. Ahmed,Azizullah Beran,Khaled Elfert,Ahmed Salih,Manasik Abdu,Yazan Abboud,Zubair Khan,Mohamed Ismail,Joseph Sleiman,Mohamed Abdallah,Ala Abdel-Jalil,Mohammad Bilal
出处
期刊:The American Journal of Gastroenterology [American College of Gastroenterology]
卷期号:118 (10S): S8-S9
标识
DOI:10.14309/01.ajg.0000949676.28499.48
摘要

Introduction: Pancreatic duct stents (PDS) are widely used for the prevention of post-ERCP pancreatitis and for pancreatic endotherapy in chronic pancreatitis patients. Several commercially available PDS are commonly utilized. However, there is a paucity of data regarding the adverse events associated with PDS placement. This study aims to investigate the reported adverse events and device failures related to PDS, utilizing the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA). Methods: Post-marketing surveillance data from January 2010 to May 2023 were extracted from the FDA's MAUDE database to analyze the outcomes associated with PDS. Reports pertaining to the use of commonly used PDS including Advanix (Boston Scientfic), Geenan (Cook endoscopy), and Zimmon (Cook endoscopy) pancreatic stents were analyzed. The primary outcomes of interest were device problems and patient-related adverse events. Statistical analysis was performed using Microsoft Excel 2010, with calculation of pooled numbers and percentages for each device and patient adverse event. Results: During the study period, a total of 540 device problems and 582 patient-related adverse events were identified. Device failures (Figure 1) were primarily attributed to device or usage problems (n=145, 26.9%), followed by off-label use (n=144, 26.7%), and material or component issues (n=120, 22.2%). The most common patient-related adverse events were reported as having no harm or consequences to patients (n=400, 68.7%). Other reported patient adverse events included inflammation (n=24, 4.1%), perforation (n=16, 2.7%), foreign body presence (n=14, 2.4%), and pancreatitis (n=10, 1.7%). The highest number of device failures was associated with Zimmon pancreatic stents (n=217, 40.2%), followed by Geenen pancreatic stents (n=216, 40%) and Advanix (n=107, 19.8%). Device or usage problems were most frequently reported with the use of Zimmon stents (n=79, 36.4%), followed by Geenen stents (n=60, 27.8%). Conclusion: Most reported device-related issues were attributed to device or usage problems, and the majority of device failures did not result in harm to patients. Information from this study can be used in improving pancreatic duct stent designs for future iterations.Figure 1.: A) Device Failures associated with pancreatic stents. B) Patient-related adverse Events associated with pancreatic stents. Device or Use Problems (Adverse Event Without Identified Device or Use Problem, no apparent adverse events, Use of Device Problem, Improper or Incorrect Procedure or Method, Device Operates Differently Than Expected), Activation, Positioning or Separation Problem (Activation Failure, Activation, Difficult or Delayed Positioning, Positioning or Separation Problem, Positioning Failure, Positioning Problem), Material or Component Problems (Break, Material Deformation, Material Integrity Problem, Material Puncture/Hole, defective device, component failing, fracture), Device Markings or Packaging Problems (Device Markings/Labelling Problem, Device Packaging), Difficulties with Device (Difficult to Advance, Difficult to Remove, Device Difficult to Setup or Prepare, failure to advance), Migration (Migration or Expulsion of Device, Migration, Detachment of Device or Device Component), Sterilization (Problem with sterilization, Contamination /Decontamination Problem), Others (Entrapment of Device, Retraction Problem; Stretched, off label use, biocompatibility, fluid/blood leakage, appropriate code not available, insufficient information, obstruction of flow, leak/splash) Pain related (Abdominal pain/pain/implant pain), Bleeding-related (Bleeding/hemorrhage, blood).
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
1秒前
zxcvbnm完成签到 ,获得积分10
2秒前
想听水星记完成签到,获得积分10
5秒前
大鼻子的新四岁完成签到,获得积分10
7秒前
aaa发布了新的文献求助20
7秒前
gjx完成签到,获得积分10
12秒前
风中的香寒完成签到 ,获得积分10
13秒前
Dliii完成签到 ,获得积分10
14秒前
16秒前
漂亮糖豆完成签到,获得积分10
19秒前
22秒前
24秒前
小狗不是抠脚兵完成签到 ,获得积分10
25秒前
可久斯基完成签到 ,获得积分10
26秒前
27秒前
简单项链发布了新的文献求助10
29秒前
不安听露完成签到 ,获得积分10
33秒前
英姑应助听话的黑猫采纳,获得10
37秒前
39秒前
完美世界应助safari采纳,获得10
41秒前
王某完成签到 ,获得积分10
42秒前
44秒前
babylow完成签到,获得积分10
46秒前
xuan发布了新的文献求助10
46秒前
大胆菲音发布了新的文献求助10
50秒前
胡亚楠完成签到,获得积分10
51秒前
情怀应助宋开心采纳,获得10
52秒前
xuan完成签到,获得积分10
54秒前
mmyhn完成签到,获得积分10
56秒前
charih完成签到 ,获得积分10
57秒前
善良的灵羊完成签到 ,获得积分10
57秒前
DDTT完成签到,获得积分10
1分钟前
宋开心完成签到,获得积分20
1分钟前
1分钟前
仁者无惧完成签到 ,获得积分10
1分钟前
1分钟前
white完成签到 ,获得积分10
1分钟前
宋开心发布了新的文献求助10
1分钟前
范丞丞完成签到 ,获得积分10
1分钟前
safari发布了新的文献求助10
1分钟前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Bandwidth Choice for Bias Estimators in Dynamic Nonlinear Panel Models 2000
HIGH DYNAMIC RANGE CMOS IMAGE SENSORS FOR LOW LIGHT APPLICATIONS 1500
Constitutional and Administrative Law 1000
The Social Work Ethics Casebook: Cases and Commentary (revised 2nd ed.). Frederic G. Reamer 800
The Experimental Biology of Bryophytes 500
Fiction e non fiction: storia, teorie e forme 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 纳米技术 计算机科学 内科学 化学工程 复合材料 物理化学 基因 遗传学 催化作用 冶金 量子力学 光电子学
热门帖子
关注 科研通微信公众号,转发送积分 5366354
求助须知:如何正确求助?哪些是违规求助? 4495093
关于积分的说明 13995268
捐赠科研通 4399366
什么是DOI,文献DOI怎么找? 2416647
邀请新用户注册赠送积分活动 1409394
关于科研通互助平台的介绍 1384488