Comparative evaluation of the volume of occlusal adjustment of repositioning occlusal devices designed by using an average value digital articulator and the jaw movement analyzer

发音器 口腔正畸科 牙合 牙科 计算机科学 医学 闭塞 心脏病学
作者
Tiwu Peng,Zhikang Yang,Teng Ma,M Zhang,Guanghui Ren
出处
期刊:Journal of Prosthetic Dentistry [Elsevier BV]
被引量:2
标识
DOI:10.1016/j.prosdent.2023.06.018
摘要

The volume of occlusal adjustment of digital occlusal devices designed with different digital occlusal articulators is unknown.The purpose of this clinical study was to evaluate and compare the clinical efficacy and volume of occlusal adjustment of digital occlusal devices designed by using an average value digital articulator and the jaw movement analyzer (JMA).Thirty participants were randomly divided into 2 groups, an Average value group and a JMA group, with 15 participants in each group. The centric relation position of the participants was determined by an experienced investigator with the aid of a leaf gauge. An intraoral scanner (TRIOS 3) was used to obtain digital scans of the maxillary and mandibular dentition and the maxillomandibular relationship record in the centric relation position. Personalized articulator parameters of participants in the JMA group were obtained by using a JMA (JMAnalyser). Different articulator parameters were used to fabricate an occlusal device in a denture design software program (exocad DentalCAD). The surface of the occlusal device was coated with a dental optical spray and then scanned by using a laboratory scanner (Kavo LS3). The process was repeated after the occlusal device was adjusted. The files of the 2 scans were imported into a reverse engineering software program, and the root mean square (RMS) values were obtained by best-fit alignment and 3-dimensional comparison. The Shapiro-Wilk normality test and homogeneity of variance test were performed, and t tests were used to evaluate differences in the RMS values between the groups (α=.05).The experimental data were generally normally distributed (P>.05). No statistically significant difference was found between the RMS values of the Average and the JMA groups (P>.05).No significant difference in the volume of occlusal adjustment was found when using occlusal devices made by using the digital average articulator or the JMA, suggesting that either method can be used to program articulators for the fabrication of occlusal devices.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
刚刚
iurhejwnej发布了新的文献求助10
刚刚
强砸完成签到,获得积分10
1秒前
Copyright应助是风动采纳,获得10
1秒前
2秒前
李健应助shenlu采纳,获得10
3秒前
3秒前
4秒前
蓝天发布了新的文献求助10
4秒前
4秒前
1111应助Jalin采纳,获得10
5秒前
10秒前
雾非雾应助仰望苍穹采纳,获得10
10秒前
奋斗梦易发布了新的文献求助10
10秒前
闪闪靖荷发布了新的文献求助10
10秒前
11秒前
完美世界应助害怕的忆梅采纳,获得10
15秒前
Wcy发布了新的文献求助10
16秒前
大模型应助Lina采纳,获得10
16秒前
李爱国应助超级绮波采纳,获得10
17秒前
yanyu应助上好佳采纳,获得30
18秒前
19秒前
Hello应助奋斗梦易采纳,获得10
19秒前
科研通AI6.4应助多洛塔采纳,获得10
19秒前
隐形曼青应助传统的故事采纳,获得10
21秒前
21秒前
22秒前
在水一方应助living笑白采纳,获得10
23秒前
彭于晏应助粱乘风采纳,获得10
23秒前
24秒前
24秒前
25秒前
25秒前
26秒前
27秒前
知道发布了新的文献求助10
27秒前
cc完成签到,获得积分20
28秒前
28秒前
arniu2008应助鱼yu采纳,获得30
29秒前
Singhi完成签到 ,获得积分10
30秒前
高分求助中
Principles of Economics, 11th Edition 10000
University Physics with Modern Physics, 16th edition 10000
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Molecular Mechanisms of Photosynthesis, 4th Edition 1000
Organic Reactions, Volume 116 1000
Current concepts in cutaneous toxicity : proceedings of the Fourth Conference on Cutaneous Toxicity, Washington, D.C., May 9-11, 1979 1000
The recovery-stress questionnaires : user manual 600
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 内科学 物理 复合材料 催化作用 细胞生物学 无机化学 光电子学 物理化学 电极 基因
热门帖子
关注 科研通微信公众号,转发送积分 7256212
求助须知:如何正确求助?哪些是违规求助? 8878297
关于积分的说明 18751055
捐赠科研通 6936493
什么是DOI,文献DOI怎么找? 3200809
关于科研通互助平台的介绍 2374982
邀请新用户注册赠送积分活动 2176369