Dosimetric comparison of robotic- and LINAC-based treatment of spine stereotactic body radiotherapy

核医学 多叶准直器 医学 赛博刀 直线粒子加速器 放射治疗 剂量学 放射外科 脊髓 放射治疗计划 放射科 梁(结构) 精神科 光学 物理
作者
H. Acar,Omer Yazici,Dilek Unal
出处
期刊:Medical Dosimetry [Elsevier]
标识
DOI:10.1016/j.meddos.2022.08.002
摘要

Abstract

To determine which treatment technique and modality would offer better dosimetric results and be preferable for spinal stereotactic body therapy (SBRT) depending on the three different regions of the vertebrae. Linear accelerator (LINAC)- and CyberKnife (CK)-based treatment techniques were compared in terms of their dosimetric quality, treatment efficiency, and delivery accuracy. Thirty previously treated patients were included in this study. Intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques were used for LINAC-based treatment, whereas CK-based treatment plans were generated for two different collimator systems: fixed and multileaf collimator (MLC). The plans were compared based on spinal cord sparing, dose homogeneity, conformity index (CI), gradient index (GI), monitor unit (MU), and beam-on time. The percentage volumes of V2Gy, V5Gy (representing volume low of the dose spillage region), V10Gy, and V20Gy (representing the volume of the high-dose spillage region) of the healthy tissue were analyzed. The CI and GI of the VMAT plans were better than those of the IMRT plans. For spinal cord sparing, the VMAT and MLC-based CK (CK-MLC) techniques were superior. The percentage of low-dose spillage regions was the lowest for IMRT and fixed cone-based CK (CK-FIX) plans. The percentage of the high-dose spillage region was the lowest for the VMAT and CK-MLC plans. In terms of treatment efficiency, the VMAT and CK-MLC plans were superior to the IMRT and CK-FIX plans. The VMAT technique lowered the MU and beam-on time values. The plan delivery accuracy of the VMAT and CK-FIX plans was better than that of the IMRT plans. VMAT is the best option for LINAC-based spinal SBRT. For CK-based spinal SBRT, MLC-based plans are preferred. If the clinic has both treatment modalities and the patient can tolerate long treatment times, CK-MLC-based treatment should be chosen because of its superiority in sparing the spinal cord and sharp dose fall-off.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
1秒前
wwww发布了新的文献求助10
1秒前
彭于晏应助阳光采纳,获得10
2秒前
Lee发布了新的文献求助10
2秒前
2秒前
lins完成签到,获得积分20
4秒前
万能图书馆应助Long采纳,获得10
4秒前
4秒前
jiayou完成签到,获得积分10
6秒前
坦率的匪发布了新的文献求助30
6秒前
深情安青应助恶恶么v采纳,获得10
6秒前
wtzhang16发布了新的文献求助10
7秒前
TQY发布了新的文献求助10
8秒前
8秒前
8秒前
言草西完成签到,获得积分10
8秒前
xuxiaotuan完成签到,获得积分10
9秒前
9秒前
余歌发布了新的文献求助10
11秒前
张小南完成签到,获得积分10
11秒前
hzw发布了新的文献求助10
11秒前
xuxiaotuan发布了新的文献求助10
12秒前
研友完成签到 ,获得积分10
12秒前
英姑应助嗳7采纳,获得10
13秒前
13秒前
红尘踏歌发布了新的文献求助10
14秒前
14秒前
陌路孤星发布了新的文献求助30
14秒前
14秒前
JK157完成签到,获得积分10
15秒前
15秒前
16秒前
17秒前
阳光发布了新的文献求助10
17秒前
18秒前
18秒前
希望天下0贩的0应助Ashley采纳,获得10
18秒前
Yuxuan发布了新的文献求助10
18秒前
下颌磨牙钳完成签到,获得积分10
19秒前
Liar应助JK157采纳,获得10
20秒前
高分求助中
Sustainability in Tides Chemistry 2000
Bayesian Models of Cognition:Reverse Engineering the Mind 800
Essentials of thematic analysis 700
A Dissection Guide & Atlas to the Rabbit 600
Very-high-order BVD Schemes Using β-variable THINC Method 568
Внешняя политика КНР: о сущности внешнеполитического курса современного китайского руководства 500
Revolution und Konterrevolution in China [by A. Losowsky] 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 催化作用 物理化学 免疫学 量子力学 细胞生物学
热门帖子
关注 科研通微信公众号,转发送积分 3124336
求助须知:如何正确求助?哪些是违规求助? 2774637
关于积分的说明 7723368
捐赠科研通 2430117
什么是DOI,文献DOI怎么找? 1290937
科研通“疑难数据库(出版商)”最低求助积分说明 621972
版权声明 600297