医学
内膜中层厚度
超声波
放射科
相关性
内科学
心脏病学
超声学家
冠状动脉疾病
颈动脉
几何学
数学
作者
Nobutaka Ikeda,Ajay Gupta,Nilanjan Dey,Soumyo Bose,Shoaib Shafique,Tadashi Arak,Elisa Cuadrado‐Godia,Luca Saba,John R. Laird,Andrew Nicolaides,Jasjit S. Suri
标识
DOI:10.1016/j.ultrasmedbio.2014.12.024
摘要
Abstract
Described here is a detailed novel pilot study on whether the SYNTAX (Synergy between percutaneous coronary intervention with TAXUS and cardiac surgery) score, a measure of coronary artery disease complexity, could be better predicted with carotid intima–media thickness (cIMT) measures using automated IMT all along the common carotid and bulb plaque compared with manual IMT determined by sonographers. Three hundred seventy consecutive patients who underwent carotid ultrasound and coronary angiography were analyzed. SYNTAX score was determined from coronary angiograms by two experienced interventional cardiologists. Unlike most methods of cIMT measurement commonly used by sonographers, our method involves a computerized automated cIMT measurement all along the carotid artery that includes the bulb region and the region proximal to the bulb (under the class of AtheroEdge systems from AtheroPoint, Roseville, CA, USA). In this study, the correlation between automated cIMT that includes bulb plaque and SYNTAX score was found to be 0.467 (p < 0.0001), compared with 0.391 (p < 0.0001) for the correlation between the sonographer's IMT reading and SYNTAX score. The correlation between the automated cIMT and the sonographer's IMT was 0.882. When compared against the radiologist's manual tracings, automated cIMT system performance had a lumen–intima error of 0.007818 ± 0.0071 mm, media–adventitia error of 0.0179 ± 0.0125 mm and automated cIMT error of 0.0099 ± 0.00988 mm. The precision of automated cIMT against the manual radiologist's reading was 98.86%. This current automated algorithm revealed a significantly stronger correlation between cIMT and coronary SYNTAX score as compared with the sonographer's cIMT measurements with multiple cardiovascular risk factors. We benchmarked our correlation between the automated cIMT that includes bulb plaque and SYNTAX score against a previously published (Ikeda et al. 2013) AtheroEdgeLink (AtheroPoint) correlation between the automated cIMT that does not include bulb plaque and SYNTAX score and had an improvement of 44.58%. By sampling cIMT in the bulb region, the automated cIMT technique improves the degree of correlation between coronary artery disease lesion complexity and carotid atherosclerosis characteristics.
科研通智能强力驱动
Strongly Powered by AbleSci AI