Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study.

标准差 扫描仪 威尔科克森符号秩检验 绝对偏差 数学 相对标准差 参考数据 口腔正畸科 生物医学工程 人工智能
作者
Vygandas Rutkūnas,Agnė Gedrimienė,Nadin Al-Haj Husain,Justinas Pletkus,Dainius Barauskis,Darius Jegelevičius,Mutlu Özcan
出处
期刊:Journal of Prosthetic Dentistry [Elsevier BV]
标识
DOI:10.1016/j.prosdent.2021.09.032
摘要

The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently.The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas.Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (α=.05).In the partially edentulous model, distance trueness mean ±standard deviation values ranged from -46.7 ±15.4 μm (TRIOS 3) to 392.1 ±314.3 μm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean ±standard deviation values ranged between -35 ±13 μm (TRIOS 4) and 117.7 ±232.3 μm (CARESTREAM). Trueness mean ±standard deviation values of angulation varied from -0.0 ±0.5 degrees (CARESTREAM) to 0.2 ±0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 ±0.2 degrees (TRIOS 3) to 0.4 ±0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 ±47.1 μm (TRIOS 4) to 107.2 ±103.5 μm (Medit) without additional artificial landmarks and from -15.0 ±45.0 μm (CARESTREAM) to -86.9 ±42.1 μm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered.Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
QWDSA完成签到,获得积分10
1秒前
彼岸花发布了新的文献求助10
1秒前
无奈行恶应助顺利一德采纳,获得10
2秒前
bxl完成签到,获得积分10
4秒前
量子星尘发布了新的文献求助10
7秒前
AlexChen发布了新的文献求助30
7秒前
董竹君发布了新的文献求助10
9秒前
BILNQPL完成签到,获得积分10
11秒前
11秒前
11秒前
11秒前
11秒前
12秒前
13秒前
xiao142发布了新的文献求助10
13秒前
13秒前
超级的笑天关注了科研通微信公众号
14秒前
hayden完成签到,获得积分20
16秒前
壮观梦易发布了新的文献求助10
17秒前
壮观梦易发布了新的文献求助10
17秒前
壮观梦易发布了新的文献求助10
17秒前
壮观梦易发布了新的文献求助10
17秒前
壮观梦易发布了新的文献求助10
17秒前
壮观梦易发布了新的文献求助10
17秒前
壮观梦易发布了新的文献求助10
17秒前
壮观梦易发布了新的文献求助30
17秒前
壮观梦易发布了新的文献求助10
17秒前
id完成签到,获得积分10
18秒前
18秒前
21秒前
xiao142完成签到,获得积分10
22秒前
ww完成签到,获得积分10
25秒前
澡雪发布了新的文献求助10
26秒前
可爱的函函应助supertkeb采纳,获得30
28秒前
31秒前
chao发布了新的文献求助20
31秒前
li发布了新的文献求助10
31秒前
32秒前
赘婿应助BILNQPL采纳,获得10
33秒前
朝朝完成签到,获得积分10
34秒前
高分求助中
A new approach to the extrapolation of accelerated life test data 1000
Picture Books with Same-sex Parented Families: Unintentional Censorship 700
ACSM’s Guidelines for Exercise Testing and Prescription, 12th edition 500
Nucleophilic substitution in azasydnone-modified dinitroanisoles 500
不知道标题是什么 500
Indomethacinのヒトにおける経皮吸収 400
Phylogenetic study of the order Polydesmida (Myriapoda: Diplopoda) 370
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 冶金 细胞生物学 免疫学
热门帖子
关注 科研通微信公众号,转发送积分 3975516
求助须知:如何正确求助?哪些是违规求助? 3519930
关于积分的说明 11200130
捐赠科研通 3256278
什么是DOI,文献DOI怎么找? 1798183
邀请新用户注册赠送积分活动 877425
科研通“疑难数据库(出版商)”最低求助积分说明 806320