医学
立体视敏度
置信区间
视力
威尔科克森符号秩检验
眼科
双眼视觉
随机对照试验
隐形眼镜
验光服务
外科
曼惠特尼U检验
光学
内科学
物理
作者
Tamara Wygnanski-Jaffe,Burton J. Kushner,Avital Moshkovitz,Michael Belkin,Oren Yehezkel
出处
期刊:Ophthalmology
[Elsevier]
日期:2023-03-01
卷期号:130 (3): 274-285
被引量:12
标识
DOI:10.1016/j.ophtha.2022.10.020
摘要
Comparing visual outcomes after use of a novel binocular eye-tracking-based home treatment (CureSight; NovaSight, Ltd) with patching.Prospective, multicenter, randomized, masked, controlled, noninferiority pivotal trial.One hundred three children 4 to < 9 years with anisometropic, small-angle strabismic or mixed-mechanism amblyopia were randomized 1:1 to either CureSight treatment or patching.The CureSight treatment uses combined anaglyph glasses and an eye tracker to induce real-time blur around the fellow eye fovea in dichoptic streamed video content. Participants used the device for 90 minutes/day, 5 days/week for 16 weeks (120 hours). The patching group received 2 hours of patching 7 days/week (224 hours). The prespecified noninferiority margin was 1 line.The primary outcome was the improvement in the amblyopic eye visual acuity (VA), modeled with a repeated measures analysis of covariance. Secondary outcomes included stereoacuity, binocular VA, and treatment adherence rates, analyzed by a 1-sample Wilcoxon test within each group and a 2-sample Wilcoxon test comparing groups. Safety outcomes included the frequency and severity of study-related adverse events (AEs).CureSight group VA improvement was found to be noninferior to patching group improvement (0.28 ± 0.13 logarithm of the minimum angle of resolution [logMAR] [P < 0.0001] and 0.23 ± 0.14 logMAR [P < 0.0001], respectively; 90% confidence interval [CI] of difference, -0.008 to 0.076). Stereoacuity improvement of 0.40 log arcseconds (P < 0.0001) and improved binocular VA (0.13 logMAR; P < 0.0001) were observed in the binocular treatment group, with similar improvements in the patching group in stereoacuity (0.40 log arcseconds; P < 0.0001) and binocular VA (0.09 logMAR; P < 0.0001), with no significant difference between improvements in the 2 groups in either stereoacuity (difference, 0; 95% CI, -0.27 to -0.27; P = 0.76) or binocular VA (difference, 0.041; 95% CI, -0.002 to 0.085; P = 0.07). The binocular treatment group had a significantly higher adherence than the patching group (91% vs. 83%; 95% CI, -4.0% to 21%; P = 0.011). No serious AEs were found.Binocular treatment was well tolerated and noninferior to patching in amblyopic children 4 to < 9 years of age. High adherence may provide an alternative treatment option for amblyopia.Proprietary or commercial disclosure may be found after the references.
科研通智能强力驱动
Strongly Powered by AbleSci AI