医学
核医学
射血分数
细胞外液
心脏成像
双重能量
心肌病
对比度(视觉)
放射科
冲程容积
心脏病学
心力衰竭
内科学
细胞外
骨质疏松症
骨矿物
人工智能
计算机科学
生物
细胞生物学
作者
Hye‐Jeong Lee,Dong Jin Im,Jong‐Chan Youn,Suyon Chang,Young Joo Suh,Yoo Jin Hong,Young Jin Kim,Jin Hur,Byoung Wook Choi
出处
期刊:Radiology
[Radiological Society of North America]
日期:2016-06-20
卷期号:280 (1): 49-57
被引量:144
标识
DOI:10.1148/radiol.2016151289
摘要
Purpose To evaluate the feasibility of equilibrium contrast material–enhanced dual-energy cardiac computed tomography (CT) to determine extracellular volume fraction (ECV) in nonischemic cardiomyopathy (CMP) compared with magnetic resonance (MR) imaging. Materials and Methods This study was approved by the institutional review board; informed consent was obtained. Seven healthy subjects and 23 patients (six with hypertrophic CMP, nine with dilated CMP, four with amyloidosis, and four with sarcoidosis) (mean age ± standard deviation, 57.33 years ± 14.82; 19 male participants [63.3%]) were prospectively enrolled. Twelve minutes after contrast material injection (1.8 mL/kg at 3 mL/sec), dual-energy cardiac CT was performed. ECV was measured by two observers independently. Hematocrit levels were compared between healthy subjects and patients with the Mann-Whitney U test. In per-subject analysis, interobserver agreement for CT was assessed with the intraclass correlation coefficient (ICC), and intertest agreement between MR imaging and CT was assessed with Bland-Altman analysis. In per-segment analysis, Student t tests in the linear mixed model were used to compare ECV on CT images between healthy subjects and patients. Results Hematocrit level was 43.44% ± 1.80 for healthy subjects and 41.23% ± 5.61 for patients with MR imaging (P = .16) and 43.50% ± 1.92 for healthy subjects and 41.35% ± 5.92 for patients with CT (P = .15). For observer 1 in per-subject analysis, ECV was 34.18% ± 8.98 for MR imaging and 34.48% ± 8.97 for CT. For observer 2, myocardial ECV was 34.42% ± 9.03 for MR imaging and 33.98% ± 9.05 for CT. Interobserver agreement for ECV at CT was excellent (ICC = 0.987). Bland-Altman analysis between MR imaging and CT showed a small bias (−0.06%), with 95% limits of agreement of −1.19 and 1.79. Compared with healthy subjects, patients with hypertrophic CMP, dilated CMP, amyloidosis, and sarcoidosis had significantly higher myocardial ECV at dual-energy equilibrium contrast-enhanced cardiac CT (all P < .01) in per-segment analysis. Conclusion Myocardial ECV with dual-energy equilibrium contrast-enhanced CT showed good agreement with MR imaging findings, suggesting the potential of myocardial tissue characterization with CT. © RSNA, 2016
科研通智能强力驱动
Strongly Powered by AbleSci AI