Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube Potential

医学 核医学 四分位间距 水当量 腹部 衰减 人体躯干 放射科
作者
Cynthia H. McCollough,Shannon L. McCollough,Justine J. Schneider,Taylor R. Moen,Jayse M. Weaver,Thomas J. Vrieze,Lifeng Yu,Shuai Leng
出处
期刊:Radiology [Radiological Society of North America]
标识
DOI:10.1148/radiol.210860
摘要

Background The size-specific dose estimate (SSDE) is a patient-focused CT dose metric. However, published size-dependent conversion factors (fsize) used to calculate SSDE were determined primarily by using phantoms; only eight to 15 patient data sets were used, all at 120 kV. Purpose To determine the effect of different tube potentials on the water-equivalent diameter (WED) and SSDE for patient CT scans of the head, chest, and abdomen. Materials and Methods This retrospective study used 250 noncontrast CT scans acquired between March 2013 and June 2017. Bony structures were segmented, and their CT numbers were modified to reflect bone attenuation at 70, 90, 110, 130, and 150 kV. Soft-tissue CT numbers were unchanged because of negligible energy dependence. fsize was measured in anthropomorphic phantoms for each tube potential and fit to an exponential function. WED and SSDE were determined for each patient at all tube potentials, regression analysis was performed relative to the WED and SSDE at 120 kV, and mean differences relative to 120 kV were calculated. Results In 250 patients (median age, 21.5 years; interquartile range, 44 years; 130 women), WED for all tube potentials was linearly related to the WED at 120 kV in all body regions (R2 = 0.995-1.000). The effect of tube potential on WED was negligible for torso examinations (Cohen d < 0.05). In the head, a medium effect size was observed at 70 kV; however, the mean absolute difference in WED was small (-0.49 cm ± 0.08 [standard deviation]; P < .001). For commonly used combinations of tube potential and patient size, the mean differences in SSDE at alternative tube potentials relative to SSDE at 120 kV were less than 5%. Conclusion At noncontrast CT, published size-dependent conversion factors accurately determined size-specific dose estimates on 250 patient scans at five tube potentials other than 120 kV. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Boone in this issue.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
aigj完成签到,获得积分10
刚刚
1秒前
1秒前
CipherSage应助拜拜拜采纳,获得10
1秒前
量子星尘发布了新的文献求助50
2秒前
专注完成签到 ,获得积分10
2秒前
A2QD发布了新的文献求助10
3秒前
竹筏过海完成签到,获得积分0
4秒前
ddc_0819发布了新的文献求助10
4秒前
perdgs发布了新的文献求助10
5秒前
sly发布了新的文献求助10
5秒前
Truman发布了新的文献求助10
5秒前
orixero应助健壮的以莲采纳,获得10
5秒前
ChinaNiu完成签到,获得积分10
5秒前
我是老大应助哈密瓜采纳,获得10
5秒前
张泽轩发布了新的文献求助10
6秒前
咔咔完成签到,获得积分10
7秒前
7秒前
石头完成签到,获得积分10
10秒前
11秒前
lyon完成签到,获得积分10
11秒前
1111应助jinyu采纳,获得10
11秒前
qin完成签到,获得积分10
11秒前
Elva完成签到,获得积分10
11秒前
pp‘s发布了新的文献求助10
11秒前
12秒前
12秒前
Amry完成签到,获得积分10
13秒前
13秒前
tom81882发布了新的文献求助50
14秒前
zz完成签到,获得积分20
14秒前
14秒前
14秒前
程老板完成签到,获得积分10
14秒前
15秒前
16秒前
凡fan发布了新的文献求助10
16秒前
搜集达人应助A2QD采纳,获得10
17秒前
17秒前
啦啦啦发布了新的文献求助10
17秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Handbook of Milkfat Fractionation Technology and Application, by Kerry E. Kaylegian and Robert C. Lindsay, AOCS Press, 1995 1000
The Social Work Ethics Casebook(2nd,Frederic G. R) 600
A novel angiographic index for predicting the efficacy of drug-coated balloons in small vessels 500
Textbook of Neonatal Resuscitation ® 500
The Affinity Designer Manual - Version 2: A Step-by-Step Beginner's Guide 500
Affinity Designer Essentials: A Complete Guide to Vector Art: Your Ultimate Handbook for High-Quality Vector Graphics 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 内科学 生物化学 物理 计算机科学 纳米技术 遗传学 基因 复合材料 化学工程 物理化学 病理 催化作用 免疫学 量子力学
热门帖子
关注 科研通微信公众号,转发送积分 5074953
求助须知:如何正确求助?哪些是违规求助? 4294878
关于积分的说明 13382686
捐赠科研通 4116573
什么是DOI,文献DOI怎么找? 2254349
邀请新用户注册赠送积分活动 1258893
关于科研通互助平台的介绍 1191820