已入深夜,您辛苦了!由于当前在线用户较少,发布求助请尽量完整的填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!祝你早点完成任务,早点休息,好梦!

Three‐Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions

印象 扫描仪 塞雷克 事后 口腔正畸科 植入 数学 拱门 显著性差异 牙科 计算机科学 材料科学 人工智能 医学 统计 工程类 外科 结构工程 复合材料 万维网 陶瓷
作者
Berkman Albayrak,Cortino Sukotjo,Alvin G. Wee,İsmail Hakkı Korkmaz,Funda Bayındır
出处
期刊:Journal of Prosthodontics [Wiley]
卷期号:30 (2): 163-170 被引量:38
标识
DOI:10.1111/jopr.13264
摘要

Abstract Purpose The accuracy of digital impressions is still controversial for complete arch implant cases. The aim of this study is to compare the accuracy of different intraoral scanners with the conventional technique in terms of trueness and precision in a complete arch implant model. Material and Methods Eight implants were inserted asymmetrically in a polyurethane edentulous mandibular model with different angulations. A 3‐dimensional (3D) reference model was obtained by scanning this polyurethane model with an optical scanner. First, digital impressions were made by using 3 different intraoral scanners: Carestream 3500 (DC), Cerec Omnicam (DO) and 3Shape Trios 3 (DT). Subsequently, a nonsplinted open tray impression technique was used for conventional impression group (C) and then the master casts were digitalized with a lab scanner. Each 10 STL files belonging to 4 different impression groups were imported to a reverse engineering program, to measure distance and angle deviations from the reference model. All statistical analyses were performed after taking absolute values of the data. After comparing the impression groups with one‐way ANOVA, the trueness and precision values were analyzed by Tukey post hoc test and 0.05 was used as the level of significance. Results The mean trueness of distance was 123.06 ± 89.83 µm for DC, 229.72 ± 121.34 µm for DO, 209.75 ± 47.07 µm for DT, and 345.32 ± 75.12 µm for C group ( p < 0.0001). While DC showed significantly lower deviation compared to DO and C, no significant difference was found between DC and DT. C showed the highest distance deviation significantly in all groups; and no significant difference was found between DO and DT groups. In angle measurements; the trueness was 0.26° ± 0.07° for DC, 0.53° ± 0.42° for DO, 0.33° ± 0.30° for DT, and 0.74° ± 0.65° for C group. There was no significant difference between the groups in terms of angular trueness ( p = 0.074). In terms of the precision for distance, the results of DC 80.43 ± 29.69 µm, DO 94.06 ± 69.96 µm, DT 35.55 ± 28.46 µm and C 66.97 ± 36.69 µm were determined ( p = 0.036). The significant difference was found only between DT and DO among all groups. Finally, angular precision was determined to be 0.19° ± 0.11° for DC, 0.30° ± 0.28° for DO, 0.22° ± 0.19° for DT, and 0.50° ± 0.38° for Group C. No significant difference was found between the groups, in terms of angular precision ( p = 0.053). Conclusions All digital impression groups yielded superior data compared to conventional technique in terms of trueness. DC formed the impression group with the highest trueness in both distance and angular measurements. The results of this in vitro study suggest the use of intraoral scanners compared to the conventional impression techniques in complete arch implant cases with high angulations.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
1秒前
heyunhua23完成签到,获得积分10
3秒前
高高千筹完成签到,获得积分10
4秒前
4秒前
嗯哼应助科研通管家采纳,获得20
4秒前
领导范儿应助Lucie采纳,获得10
4秒前
乐乐应助科研通管家采纳,获得10
5秒前
5秒前
zijian应助科研通管家采纳,获得10
5秒前
5秒前
Zzan完成签到 ,获得积分10
5秒前
7秒前
俭朴一笑发布了新的文献求助10
10秒前
zhul09完成签到,获得积分10
11秒前
类器官牛逼完成签到,获得积分20
12秒前
Hana完成签到 ,获得积分10
12秒前
13秒前
Owen应助wangchenjie采纳,获得10
14秒前
15秒前
19秒前
高高板栗发布了新的文献求助20
23秒前
23秒前
czb666发布了新的文献求助10
23秒前
24秒前
27秒前
29秒前
JamesPei应助nqbscxttdh采纳,获得30
29秒前
31秒前
端庄煎饼应助花啦啦采纳,获得10
32秒前
34秒前
Erictancqmu发布了新的文献求助10
37秒前
42秒前
领导范儿应助Akaashi采纳,获得10
42秒前
沐风发布了新的文献求助10
43秒前
郑总完成签到 ,获得积分10
44秒前
scn666发布了新的文献求助10
48秒前
48秒前
49秒前
高大冷菱完成签到 ,获得积分10
50秒前
55秒前
高分求助中
Production Logging: Theoretical and Interpretive Elements 2000
Very-high-order BVD Schemes Using β-variable THINC Method 1200
BIOLOGY OF NON-CHORDATES 1000
进口的时尚——14世纪东方丝绸与意大利艺术 Imported Fashion:Oriental Silks and Italian Arts in the 14th Century 800
Autoregulatory progressive resistance exercise: linear versus a velocity-based flexible model 550
Education and Upward Social Mobility in China: Imagining Positive Sociology with Bourdieu 500
Zeitschrift für Orient-Archäologie 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 物理化学 催化作用 细胞生物学 免疫学 冶金
热门帖子
关注 科研通微信公众号,转发送积分 3353291
求助须知:如何正确求助?哪些是违规求助? 2977976
关于积分的说明 8683081
捐赠科研通 2659190
什么是DOI,文献DOI怎么找? 1456109
科研通“疑难数据库(出版商)”最低求助积分说明 674264
邀请新用户注册赠送积分活动 664978