Mehdi Vahdati,A. I. Sayma,Christopher Freeman,M. Imregun
出处
期刊:Journal of turbomachinery [ASME International] 日期:2004-08-27卷期号:127 (2): 349-351被引量:101
标识
DOI:10.1115/1.1861912
摘要
Abstract This paper describes a novel way of prescribing computational fluid dynamics (CFD) boundary conditions for axial-flow compressors. The approach is based on extending the standard single passage computational domain by adding an intake upstream and a variable nozzle downstream. Such a route allows us to consider any point on a given speed characteristic by simply modifying the nozzle area, the actual boundary conditions being set to atmospheric ones in all cases. Using a fan blade, it is shown that the method not only allows going past the stall point but also captures the typical hysteresis loop behavior of compressors.