有效扩散系数
医学
磁共振成像
乳腺癌
磁共振弥散成像
乳房磁振造影
磁共振弥散加权成像
核医学
内科学
癌症
放射科
乳腺摄影术
作者
Mami Iima,Masako Kataoka,Maya Honda,Akane Ohashi,Ayami Ohno Kishimoto,Rie Ota,Ryuji Uozumi,Yuta Urushibata,Thorsten Feiweier,Masakazu Toi,Yuji Nakamoto
标识
DOI:10.1097/rli.0000000000000766
摘要
Introduction The aim of this study was to investigate the variation of apparent diffusion coefficient (ADC) values with diffusion time according to breast tumor type and prognostic biomarkers expression. Materials and Methods A total of 201 patients with known or suspected breast tumors were prospectively enrolled in this study, and 132 breast tumors (86 malignant and 46 benign) were analyzed. Diffusion-weighted imaging scans with 2 diffusion times were acquired on a clinical 3-T magnetic resonance imaging scanner using oscillating and pulsed diffusion-encoding gradients (effective diffusion times, 4.7 and 96.6 milliseconds) and b values of 0 and 700 s/mm 2 . Diagnostic performances to differentiate malignant and benign breast tumors for ADC values at short and long diffusion times (ADC short and ADC long ), ΔADC (the rate of change in ADC values with diffusion time), ADC 0–1000 (ADC value from a standard protocol), and standard reading including dynamic contrast-enhanced magnetic resonance imaging (BI-RADS) were investigated. The correlations of ADC short , ADC long , and ΔADC values with hormone receptor expression and breast cancer subtypes were also analyzed. Results The ADC values were lower, and ΔADC was higher in malignant tumors compared with benign tumors. The specificity of ADC values at all diffusion times and ΔADC values for differentiating malignant and benign breast tumors was superior to that of BI-RADS (87.0%–95.7% vs 73.9%), whereas the sensitivity was inferior (87.2%–90.7% vs 100%). Lower ADC short and ADC 0–1000 in ER-positive compared with ER-negative cancers (false discovery rate [FDR]–adjusted P = 0.037 and 0.018, respectively) and lower ADC short , ADC long , and ADC 0–1000 in progesterone receptor–positive compared with progesterone receptor–negative cancers (FDR-adjusted P = 0.037, 0.036, and 0.018, respectively) were found. Ki-67–positive cancers had larger ΔADCs than Ki-67–negative cancers (FDR-adjusted P = 0.018). Conclusions The ADC values vary with different diffusion time and vary in correlation with molecular biomarkers, especially Ki-67. Those results suggest that the diffusion time, which should be reported, might be a useful parameter to consider for breast cancer management.
科研通智能强力驱动
Strongly Powered by AbleSci AI