期刊:Lecture notes in electrical engineering日期:2012-12-05卷期号:: 691-697
标识
DOI:10.1007/978-1-4471-4802-9_91
摘要
This research is based on high performance liquid chromatographic method for the determination of bisphenol A, nonylphenol and octylphenol in sewage. Sewage samples use dispersive liquid–liquid extraction-pre column derivatization-High performance liquid chromatography method for the determination. Dichloromethane is extracting agent. Acetonitrile and water (V:V = 90:10) are mobile phase. Bisphenol A, nonylphenol and octylphenol detect by Inertsil ODS-P column (5 μm, 250 × 4.6 mm) after the separation of fluorescence. Fluorescence excitation wavelength is 227 nm. The emission wavelength is 313 nm. Sample complete in 6 min within the peak. Linear range is 0.1−10 mg/L. In 0.1, 0.5 and 1 mg/L three concentrations of added level of sewage recovery of samples are respectively 94.7–106.8 %. The method is simple, rapid and economic actual samples. It can be used for sewage.