This paper presents a risk assessment method for a ship’s power system under the conditions of an engine room fire based on the expert comprehensive evaluation (ECE) method combined with the fuzzy fault tree analysis (FFTA) method. The composition of the main engine system in the engine room and the failure logic of each subsystem were analyzed, and the fuzzy fault tree of a ship engine room fire was constructed. The probability of system failure and the importance of basic events were calculated. The fire safety risk assessment model was established using the safety risk matrix. The risk assessment of a ship engine room fire was implemented. The results demonstrated that the fire frequency of the ship engine room was 5.232 × 10−6 h−1. The fire risk of the main engine fuel system was the highest. Fuel leakages from diesel supply tanks and heavy fuel oil tanks are the main cause of accidents. The proposed method eliminated the influence of incomplete statistics in the risk assessment process and improved the accuracy and credibility of the reassessment results.