作者
Yuefan Liu,Suxin Zhou,Yixin Kuang,Xiaoying Feng,Zhuo Wang,Zitao Shen,Ningbo Zhou,Juan Zheng,Gangfeng Ouyang
摘要
Polycyclic aromatic hydrocarbons (PAHs) are high-profile organic pollutants to be poisonous, carcinogenic, and mutagenic, and widely distributed at trace levels in the environment. In order to effectively enrich PAHs, two stable covalent organic frameworks (COFs, TAPT-OMe-PDA and TPB-DMTP) were prepared by combining 2,4,6-tri(4-aminophenyl)-1,3,5-triazine (TAPT) and 1,3,5-tri(4-aminophenyl) benzene (TAPB) with 2,5-dimethoxy-phenyl-1,4-diformaldehyde (OMe-PDA), respectively. Even though the surface area of TAPT-OMe-PDA was much lower than that of TPB-DMTP, it still demonstrated much better extraction efficiencies towards PAHs as the solid phase microextraction (SPME) coating. Therefore, the TAPT-OMe-PDA coated fiber was coupled with gas chromatography-mass spectrometry (GC-MS) to establish a practical and sensitive method, after the extraction parameters (extraction time, extraction temperature, desorption temperature, desorption time, salt concentration and pH) were optimized. This developed analytical method showed wide liner ranges, low limits of detection, good repeatability and reproducibility. Finally, five PAHs in three water samples were detected and quantified precisely (2.72–38.7 ng L−1) with satisfactory recoveries (88.3%–118 %).