医学
超声造影
髓内棒
超声波
脊髓
神经外科
放射科
绳索
灌注
外科
精神科
作者
Ignazio G. Vetrano,Antonio Giulio Gennari,Alessandra Erbetta,Francesco Acerbi,Vittoria Nazzi,Francesco DiMeco,Francesco Prada
标识
DOI:10.1016/j.ultrasmedbio.2020.10.017
摘要
Intra-operative contrast-enhanced ultrasound (CEUS) is a relatively standardized procedure in brain neurosurgery, but it is still underused in spinal cord and intramedullary tumor evaluation. We reviewed and analyzed the intra-operative data from a surgical series of patients harboring intramedullary spinal cord tumors who underwent surgery under CEUS guidance. CEUS was performed in 12 patients (age range: 13–55 y); all lesions had ill-defined boundaries or peritumoral cysts at preliminary intra-operative B-mode ultrasound. CEUS highlighted the tumors in all cases. The contrast agent's spinal distribution revealed different phases (arterial, peak, washout), as observed in the brain, but these appeared to be slower and less intense. In our experience, intra-operative CEUS allows surgeons to assess spinal cord perfusion and highlight intramedullary tumors in real time. As for other imaging modalities, ultrasound contrast agents add valuable information over baseline imaging, and their use should be fostered to better understand microbubble distribution dynamics.