Machine Learning–Based Three-Dimensional Echocardiographic Quantification of Right Ventricular Size and Function: Validation Against Cardiac Magnetic Resonance

医学 再现性 心脏磁共振 心室功能 射血分数 磁共振成像 心脏磁共振成像 心功能曲线 核医学 心脏病学 放射科 人工智能 机器学习 计算机科学 心力衰竭 统计 数学
作者
Davide Genovese,Nina Rashedi,Lynn Weinert,Akhil Narang,Karima Addetia,Amit R. Patel,David Prater,Alexandra Gonçalves,Victor Mor‐Avi,Roberto M. Lang
出处
期刊:Journal of The American Society of Echocardiography [Elsevier]
卷期号:32 (8): 969-977 被引量:74
标识
DOI:10.1016/j.echo.2019.04.001
摘要

•Machine-learning software for quantification of right ventricular function was tested. •Accurate, fully-automated measurements are possible in 32% of unselected patients. •With minimal editing, accurate measurements were obtained in the remaining patients. Background Three-dimensional echocardiography (3DE) allows accurate and reproducible measurements of right ventricular (RV) size and function. However, widespread implementation of 3DE in routine clinical practice is limited because the existing software packages are relatively time-consuming and skill demanding. The aim of this study was to test the accuracy and reproducibility of new machine learning– (ML-) based, fully automated software for three-dimensional quantification of RV size and function. Methods Fifty-six unselected patients with a wide range of RV size and function and image quality, referred for clinically indicated cardiac magnetic resonance (CMR) imaging, underwent a transthoracic 3DE exam on the same day. End-systolic and end-diastolic RV volumes (ESV, EDV) and ejection fraction (EF) were measured using the ML-based algorithm and compared with CMR reference values using Bland-Altman and linear regression analyses. Results RV function quantification by echocardiography was feasible in all patients. The automatic approach was accurate in 32% patients with analysis time of 15 ± 1 seconds and 100% reproducible. Endocardial contour editing was necessary after the automated postprocessing in the remaining 68% patients, prolonging analysis time to 114 ± 71 seconds. With these minimal adjustments, RV volumes and EF measurements were accurate in comparison with CMR reference (biases: EDV, −25.6 ± 21.1 mL; ESV, −7.4 ± 16 mL; EF, −3.3% ± 5.2%) and showed excellent reproducibility reflected by coefficients of variation <7% and intraclass correlations ≥0.95 for all measurements. Conclusions The new ML-based 3DE algorithm provided accurate and completely reproducible RV volume and EF measurements in one-third of unselected patients without any boundary editing. In the remaining patients, quick minimal editing resulted in reasonably accurate measurements with excellent reproducibility. This approach provides a promising solution for fast three-dimensional quantification of RV size and function. Three-dimensional echocardiography (3DE) allows accurate and reproducible measurements of right ventricular (RV) size and function. However, widespread implementation of 3DE in routine clinical practice is limited because the existing software packages are relatively time-consuming and skill demanding. The aim of this study was to test the accuracy and reproducibility of new machine learning– (ML-) based, fully automated software for three-dimensional quantification of RV size and function. Fifty-six unselected patients with a wide range of RV size and function and image quality, referred for clinically indicated cardiac magnetic resonance (CMR) imaging, underwent a transthoracic 3DE exam on the same day. End-systolic and end-diastolic RV volumes (ESV, EDV) and ejection fraction (EF) were measured using the ML-based algorithm and compared with CMR reference values using Bland-Altman and linear regression analyses. RV function quantification by echocardiography was feasible in all patients. The automatic approach was accurate in 32% patients with analysis time of 15 ± 1 seconds and 100% reproducible. Endocardial contour editing was necessary after the automated postprocessing in the remaining 68% patients, prolonging analysis time to 114 ± 71 seconds. With these minimal adjustments, RV volumes and EF measurements were accurate in comparison with CMR reference (biases: EDV, −25.6 ± 21.1 mL; ESV, −7.4 ± 16 mL; EF, −3.3% ± 5.2%) and showed excellent reproducibility reflected by coefficients of variation <7% and intraclass correlations ≥0.95 for all measurements. The new ML-based 3DE algorithm provided accurate and completely reproducible RV volume and EF measurements in one-third of unselected patients without any boundary editing. In the remaining patients, quick minimal editing resulted in reasonably accurate measurements with excellent reproducibility. This approach provides a promising solution for fast three-dimensional quantification of RV size and function.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI

祝大家在新的一年里科研腾飞
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
5秒前
Aixx完成签到 ,获得积分10
5秒前
6秒前
6秒前
7秒前
小蘑菇应助牟白容采纳,获得10
8秒前
体贴的叛逆者完成签到,获得积分10
8秒前
9秒前
鄂问玉完成签到 ,获得积分20
10秒前
微风发布了新的文献求助10
10秒前
11秒前
yuchao_0110发布了新的文献求助10
11秒前
四方发布了新的文献求助10
16秒前
李爱国应助酷炫小笼包采纳,获得10
18秒前
在水一方应助方羽采纳,获得10
20秒前
威武的香岚完成签到,获得积分20
20秒前
22秒前
22秒前
克猫猫发布了新的文献求助10
25秒前
zjcbk985完成签到,获得积分10
26秒前
付霖云完成签到 ,获得积分10
27秒前
轻松的冥王星完成签到,获得积分10
27秒前
小六完成签到,获得积分10
28秒前
28秒前
丘比特应助wzx采纳,获得10
30秒前
32秒前
33秒前
科研通AI2S应助背后的大侠采纳,获得10
34秒前
35秒前
pluto应助高兴的幻柏采纳,获得10
38秒前
zhaoty完成签到,获得积分10
39秒前
tingtingzhang完成签到 ,获得积分10
39秒前
无花果应助乐观的丹琴采纳,获得10
40秒前
东郭海白发布了新的文献求助10
41秒前
NexusExplorer应助zeven采纳,获得100
42秒前
南风应助玩儿采纳,获得10
43秒前
45秒前
46秒前
47秒前
47秒前
高分求助中
Востребованный временем 2500
The Three Stars Each: The Astrolabes and Related Texts 1500
Very-high-order BVD Schemes Using β-variable THINC Method 990
Les Mantodea de Guyane 800
Mantids of the euro-mediterranean area 700
Field Guide to Insects of South Africa 660
Mantodea of the World: Species Catalog 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 物理化学 催化作用 细胞生物学 免疫学 冶金
热门帖子
关注 科研通微信公众号,转发送积分 3396278
求助须知:如何正确求助?哪些是违规求助? 3006111
关于积分的说明 8819637
捐赠科研通 2693161
什么是DOI,文献DOI怎么找? 1475149
科研通“疑难数据库(出版商)”最低求助积分说明 682393
邀请新用户注册赠送积分活动 675566