医学
心脏病学
内科学
心肌梗塞
射血分数
植入式心律转复除颤器
危险系数
置信区间
心力衰竭
作者
Kristina H. Haugaa,Marit Kristine Smedsrud,Torkel Steen,Erik Kongsgaard,Jan Pål Loennechen,Terje Skjærpe,Jens‐Uwe Voigt,Rik Willems,Gunnar Smith,Otto A. Smiseth,Jan Amlie,Thor Edvardsen
标识
DOI:10.1016/j.jcmg.2009.11.012
摘要
The aim of this study was to investigate whether myocardial strain echocardiography can predict ventricular arrhythmias in patients after myocardial infarction (MI). Left ventricular (LV) ejection fraction (EF) is insufficient for selecting patients for implantable cardioverter-defibrillator (ICD) therapy after MI. Electrical dispersion in infarcted myocardium facilitates malignant arrhythmia. Myocardial strain by echocardiography can quantify detailed regional and global myocardial function and timing. We hypothesized that electrical abnormalities in patients after MI will lead to LV mechanical dispersion, which can be measured as regional heterogeneity of contraction by myocardial strain. We prospectively included 85 post-MI patients, 44 meeting primary and 41 meeting secondary ICD prevention criteria. After 2.3 years (range 0.6 to 5.5 years) of follow-up, 47 patients had no and 38 patients had 1 or more recorded arrhythmias requiring appropriate ICD therapy. Longitudinal strain was measured by speckle tracking echocardiography. The SD of time to maximum myocardial shortening in a 16-segment LV model was calculated as a parameter of mechanical dispersion. Global strain was calculated as average strain in a 16-segment LV model. The EF did not differ between ICD patients with and without arrhythmias occurring during follow-up (34 ± 11% vs. 35 ± 9%, p = 0.70). Mechanical dispersion was greater in ICD patients with recorded ventricular arrhythmias compared with those without (85 ± 29 ms vs. 56 ± 13 ms, p < 0.001). By Cox regression, mechanical dispersion was a strong and independent predictor of arrhythmias requiring ICD therapy (hazard ratio: 1.25 per 10-ms increase, 95% confidence interval: 1.1 to 1.4, p < 0.001). In patients with an EF >35%, global strain showed better LV function in those without recorded arrhythmias (−14.0% ± 4.0% vs. −12.0 ± 3.0%, p = 0.05), whereas the EF did not differ (44 ± 8% vs. 41 ± 5%, p = 0.23). Mechanical dispersion was more pronounced in post-MI patients with recurrent arrhythmias. Global strain was a marker of arrhythmias in post-MI patients with relatively preserved ventricular function. These novel parameters assessed by myocardial strain may add important information about susceptibility for ventricular arrhythmias after MI.
科研通智能强力驱动
Strongly Powered by AbleSci AI