化学
色谱法
串联质谱法
异亮氨酸
质谱法
肽
液相色谱-质谱法
促红细胞生成素
亮氨酸
串联质量标签
重组DNA
氨基酸
生物化学
蛋白质组学
定量蛋白质组学
生物
内分泌学
基因
作者
Mark Timms,Rohan Steel
摘要
The proteotypic human EPO peptides YLLEAK (T4), SLTTLLR (T11), TITADTFR (T14), and VYSNFLR (T17) are often used to confirm the presence of recombinant human EPO (rhEPO) in equine samples. Each of these peptides contains one or more isomeric leucine or isoleucine amino acids, raising the possibility that a simple leucine/isoleucine substitution could lead to a false identification when compared with a rhEPO reference standard. To examine this possibility variants of these four peptides were analysed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). These studies indicate that confirmation of rhEPO in equine samples by immuno-affinity capture and LC-MS/MS analysis is true and accurate. It was also found that chromatography played a greater role in determining LC-MS/MS specificity than tandem mass spectrometry and that, in the case of more hydrophilic peptides, the accuracy of peptide identification could be enhanced by the inclusion of 13 C and 15 N labelled peptide internal standards.
科研通智能强力驱动
Strongly Powered by AbleSci AI