医学
血管造影
图像质量
放射科
断层摄影术
核医学
造影剂
对比噪声比
图像噪声
灌注扫描
灌注
最大强度投影
人工智能
计算机科学
图像(数学)
作者
Ewoud J. Smit,Evert‐Jan Vonken,Irene C. van der Schaaf,Adriënne M. Mendrik,Jan Willem Dankbaar,Alexander D. Horsch,Tom van Seeters,Bram van Ginneken,Mathias Prokop
出处
期刊:Radiology
[Radiological Society of North America]
日期:2012-02-14
卷期号:263 (1): 216-225
被引量:69
标识
DOI:10.1148/radiol.11111068
摘要
To suggest a simple and robust technique used to reconstruct high-quality computed tomographic (CT) angiographic images from CT perfusion data and to compare it with currently used CT angiography techniques.Institutional review board approval was waived for this retrospective study, which included 25 consecutive patients who had had a stroke. Temporal maximum intensity projection (tMIP) CT angiographic images were created by using prior temporal filtering as a timing-insensitive technique to produce CT angiographic images from CT perfusion data. The temporal filter strength was optimized to gain maximal contrast-to-noise ratios (CNRs) in the circle of Willis. The resulting timing-invariant (TI) CT angiography was compared with standard helical CT angiography, the arterial phase of dynamic CT angiography, and nonfiltered tMIP CT angiography. Vascular contrast, image noise, and CNR were measured. Four experienced observers scored all images for vascular noise, vascular contour, detail of small and medium arteries, venous superimposition, and overall image quality in a blinded side-by-side comparison. Measurements were compared with a paired t test; P ≤ .05 indicated a significant difference.On average, optimized temporal filtering in TI CT angiography increased CNR by 18% and decreased image noise by 18% at the expense of a decrease in vascular contrast of 3% when compared with nonfiltered tMIP CT angiography. CNR, image noise, vascular noise, vascular contour, detail visibility of small and medium arteries, and overall image quality of TI CT angiograms were superior to those of standard CT angiography, tMIP CT angiography, and the arterial phase of dynamic CT angiography at a vascular contrast that was similar to that of standard CT angiography. Venous superimposition was similar for all techniques. Image quality of the arterial phase of dynamic CT angiography was rated inferior to that of standard CT angiography.TI CT angiographic images constructed by using temporally filtered tMIP CT angiographic data have excellent image quality that is superior to that achieved with currently used techniques, but they suffer from modest venous superimposition.
科研通智能强力驱动
Strongly Powered by AbleSci AI