医学
支架
靶病变
再狭窄
病变
狭窄
裸金属支架
紫杉醇
冠状动脉疾病
裸金属
药物洗脱支架
放射科
动脉
人口
外科
心肌梗塞
内科学
经皮冠状动脉介入治疗
化疗
环境卫生
作者
Gregg W. Stone,Stephen G. Ellis,Louis Cannon,J. Tift Mann,Joel Greenberg,Douglas Spriggs,Charles O’Shaughnessy,Samuel J. DeMaio,Patrick Hall,Jeffrey J. Popma,Joerg Koglin,Mary E. Russell,for the TAXUS V Investigators
出处
期刊:JAMA
[American Medical Association]
日期:2005-09-13
卷期号:294 (10): 1215-1215
被引量:763
标识
DOI:10.1001/jama.294.10.1215
摘要
Compared with bare metal stents, drug-eluting stents reduce restenosis in noncomplex lesions. The utility of drug-eluting stents has not been evaluated in more difficult stenoses.To investigate the safety and efficacy of the polymer-based, slow-release paclitaxel-eluting stent in a patient population with more complex lesions than previously studied.Prospective, placebo-controlled, double-blind, multicenter randomized trial conducted from February 2003 to March 2004 at 66 academic and community-based institutions with 1156 patients who underwent stent implantation in a single coronary artery stenosis (vessel diameter, 2.25-4.0 mm; lesion length, 10-46 mm), including 664 patients (57.4%) with complex or previously unstudied lesions (requiring 2.25-mm, 4.0-mm, and/or multiple stents) and 9-month clinical and angiographic follow-up.Patients were randomly assigned to receive 1 or more bare metal stents (n = 579) or identical-appearing paclitaxel-eluting stents (n = 577).Ischemia-driven target vessel revascularization at 9 months.Baseline characteristics were well matched. Diabetes was present in 31% of patients. The mean (SD) reference vessel diameter was 2.69 (0.57) mm, the reference lesion length was 17.2 (9.2) mm, and 78% of lesions were type B2/C. A mean (SD) of 1.38 (0.58) stents (total mean [SD] length, 28.4 [13.1] mm) were implanted per lesion; 33% of lesions required multiple stents. Stents that were 2.25 mm and 4.0 mm in diameter were used in 18% and 17% of lesions, respectively. Compared with bare metal stents, paclitaxel-eluting stents reduced the 9-month rate of target lesion revascularization from 15.7% to 8.6% (P<.001) and target vessel revascularization from 17.3% to 12.1% (P = .02). Similar rates were observed for cardiac death or myocardial infarction (5.5% for bare metal stent group vs 5.7% for paclitaxel-eluting stent group) and stent thrombosis (0.7% in both groups). Angiographic restenosis was reduced from 33.9% to 18.9% in the entire study cohort (P<.001), including among patients receiving 2.25-mm stents (49.4% vs 31.2%; P = .01), 4.0-mm stents (14.4% vs 3.5%; P = .02), and multiple stents (57.8% vs 27.2%; P<.001).Compared with a bare metal stent, implantation of the paclitaxel-eluting stent in a patient population with complex lesions effectively reduces clinical and angiographic restenosis.
科研通智能强力驱动
Strongly Powered by AbleSci AI