Housekeeping proteins are typically chosen as internal loading controls for Western blot analysis because of their high, relatively constant expression. It was previously reported that antibodies against β-actin did not reliably identify differences in sample loading, and extended antibody incubations caused a failure to discriminate differences in target protein levels. Here, β-actin and GAPDH were evaluated as loading controls using near-infrared fluorescence. A load-dependent response in signal intensity was observed over a 250-fold range of sample concentrations, with R2 values as high as 0.9939. Longer antibody incubations continued to detect differences in protein level and load-dependent responses became more linear.