Refik Kavsur,Christian Schaefer,Max Jonathan Stumpf,Marcel Weber,Atsushi Sugiura,Marc Ulrich Becher,Sebastian Zimmer,Georg Nickenig,Nadjib Schahab
出处
期刊:Angiology
[SAGE Publishing]
日期:2023-08-12
被引量:1
标识
DOI:10.1177/00033197231195647
摘要
The present study aimed to analyze common carotid artery strain properties in patients (n = 59) with severe aortic valve stenosis who underwent transcatheter aortic valve replacement (TAVR). Arterial compliance of the common carotid artery was assessed by ultrasound speckle-tracking before and after TAVR. For sub-analysis the study cohort was divided according to aortic valve area <.75 cm2 (n = 30) vs ≥.75 cm2 (n = 29). Comparison of pre- and post-procedural strain variables showed an improvement in median radial velocity (P < .0001), radial displacement (P = .007), circumferential strain (P = .004), radial strain rate (P = .023), and circumferential strain rate (P < .0001), while the increase of radial strain showed a trend (P = .082). Analysis of aortic valve area revealed an inverse correlation between aortic valve area and the differences (post-procedural-pre-procedural values) for radial strain rate, and circumferential strain. Moreover, sub-analysis revealed that the increase of carotid strain variables before and after TAVR were more pronounced in the sub-group of aortic valve area .75 vs ≥.75 cm2. TAVR led to a reduction of arterial wall stiffness of the common carotid artery assessed by ultrasound speckle-tracking. The decrease of arterial wall stiffness after TAVR was more pronounced in more severe aortic valve stenosis.