医学
磁共振成像
导航系统
立体视
解剖(医学)
内窥镜检查
窦(植物学)
计算机视觉
放射科
人工智能
计算机科学
植物
生物
属
作者
Ryan A. Bartholomew,Haoyin Zhou,Maud Boreel,Krish Suresh,Saksham Gupta,Margaret B. Mitchell,Christopher S. Hong,Stella E. Lee,Timothy R. Smith,Jeffrey P. Guenette,C. Eduardo Corrales,Jagadeesan Jayender
出处
期刊:JAMA otolaryngology-- head & neck surgery
[American Medical Association]
日期:2024-03-07
卷期号:150 (4): 318-318
被引量:2
标识
DOI:10.1001/jamaoto.2024.0013
摘要
Importance Image guidance is an important adjunct for endoscopic sinus and skull base surgery. However, current systems require bulky external tracking equipment, and their use can interrupt efficient surgical workflow. Objective To evaluate a trackerless surgical navigation system using 3-dimensional (3D) endoscopy and simultaneous localization and mapping (SLAM) algorithms in the anterior skull base. Design, Setting, and Participants This interventional deceased donor cohort study and retrospective clinical case study was conducted at a tertiary academic medical center with human deceased donor specimens and a patient with anterior skull base pathology. Exposures Participants underwent endoscopic endonasal transsphenoidal dissection and surface model reconstruction from stereoscopic video with registration to volumetric models segmented from computed tomography (CT) and magnetic resonance imaging. Main Outcomes and Measures To assess the fidelity of surface model reconstruction and accuracy of surgical navigation and surface-CT model coregistration, 3 metrics were calculated: reconstruction error, registration error, and localization error. Results In deceased donor models (n = 9), high-fidelity surface models of the posterior wall of the sphenoid sinus were reconstructed from stereoscopic video and coregistered to corresponding volumetric CT models. The mean (SD; range) reconstruction, registration, and localization errors were 0.60 (0.24; 0.36-0.93), 1.11 (0.49; 0.71-1.56) and 1.01 (0.17; 0.78-1.25) mm, respectively. In a clinical case study of a patient who underwent a 3D endoscopic endonasal transsphenoidal resection of a tubercular meningioma, a high-fidelity surface model of the posterior wall of the sphenoid was reconstructed from intraoperative stereoscopic video and coregistered to a volumetric preoperative fused CT magnetic resonance imaging model with a root-mean-square error of 1.38 mm. Conclusions and Relevance The results of this study suggest that SLAM algorithm–based endoscopic endonasal surgery navigation is a novel, accurate, and trackerless approach to surgical navigation that uses 3D endoscopy and SLAM-based algorithms in lieu of conventional optical or electromagnetic tracking. While multiple challenges remain before clinical readiness, a SLAM algorithm–based endoscopic endonasal surgery navigation system has the potential to improve surgical efficiency, economy of motion, and safety.
科研通智能强力驱动
Strongly Powered by AbleSci AI