斯托克斯参量
压缩传感
偏振器
光学
成像光谱仪
分光计
缓速器
计算机科学
极化(电化学)
图像质量
光谱成像
物理
迭代重建
旋光法
校准
计算机视觉
人工智能
图像(数学)
散射
化学
材料科学
双折射
物理化学
复合材料
量子力学
作者
Feng Han,Tingkui Mu,Haoyang Li,Abudusalamu Tuniyazi
标识
DOI:10.1117/1.apn.2.3.036009
摘要
Compressive full-Stokes spectropolarimetric imaging (SPI), integrating passive polarization modulator (PM) into general imaging spectrometer, is powerful enough to capture high-dimensional information via incomplete measurement; a reconstruction algorithm is needed to recover 3D data cube (x, y, and λ) for each Stokes parameter. However, existing PMs usually consist of complex elements and enslave to accurate polarization calibration, current algorithms suffer from poor imaging quality and are subject to noise perturbation. In this work, we present a single multiple-order retarder followed a polarizer to implement passive spectropolarimetric modulation. After building a unified forward imaging model for SPI, we propose a deep image prior plus sparsity prior algorithm for high-quality reconstruction. The method based on untrained network does not need training data or accurate polarization calibration and can simultaneously reconstruct the 3D data cube and achieve self-calibration. Furthermore, we integrate the simplest PM into our miniature snapshot imaging spectrometer to form a single-shot SPI prototype. Both simulations and experiments verify the feasibility and outperformance of our SPI scheme. It provides a paradigm that allows general spectral imaging systems to become passive full-Stokes SPI systems by integrating the simplest PM without changing their intrinsic mechanism.
科研通智能强力驱动
Strongly Powered by AbleSci AI