发音器
中心关系
口腔正畸科
牙科
群(周期表)
跟踪(教育)
计算机科学
人工智能
医学
计算机视觉
闭塞
外科
心理学
教育学
有机化学
化学
作者
Marta Revilla‐León,Rubén Agustín‐Panadero,Jonathan M. Zeitler,Abdul Basir Barmak,Burak Yılmaz,John C. Kois,Jorge Alonso Pérez‐Barquero
标识
DOI:10.1016/j.prosdent.2022.12.007
摘要
Statement of problem Digital systems including intraoral scanners (IOSs) and optical jaw tracking systems can be used to acquire the maxillomandibular relationship at the centric relation (CR). However, the discrepancy of the maxillomandibular relationship recorded at the CR position when using digital methods remains uncertain. Purpose The purpose of this clinical study was to compare the accuracy of the maxillomandibular relationship recorded at the CR position using a conventional procedure, 4 different IOSs, and an optical jaw tracking system. Material and methods A completely dentate volunteer was selected. A Kois deprogrammer (KD) was fabricated. Six groups were created based on the technique used to obtain diagnostic casts and record the maxillomandibular relationship at the CR position: conventional procedures (CNV group), 4 IOS groups: TRIOS4 (TRIOS4 group), iTero Element 5D (iTero group), i700 wireless (i700 group), Primescan (Primescan group), and a jaw tracking system (Modjaw) (Modjaw group) (n=10). In the CNV group, conventional diagnostic stone casts were obtained. A facebow record was used to mount the maxillary cast on an articulator (Panadent). The KD was used to obtain a CR record for mounting the mandibular cast, and the mounted casts were digitized by using a scanner (T710) to acquire the reference scans. In the TRIOS group, intraoral scans were obtained and duplicated 10 times. The KD was used to obtain a bilateral virtual occlusal record at the CR position. To acquire the specimens of the iTero, i700, and Primescan groups, the procedures in the TRIOS4 group were followed, but with the corresponding IOS. In the Modjaw group, the KD was used to record and export the maxillomandibular relationship at the CR position. Articulated virtual casts of each group were exported. Thirty-six interlandmark linear measurements were computed on both the reference and experimental scans. The distances obtained on the reference scan were used to calculate the discrepancies with the distances obtained on each experimental scan. The data were analyzed by using 1-way ANOVA followed by the pairwise comparison Tukey tests (α=.05). Results The trueness and precision of the maxillomandibular relationship record were significantly affected by the technique used (P<.001). The maxillomandibular relationship trueness values from high to low were iTero (0.14 ±0.09 mm), followed by the Modjaw (0.20 ±0.04 mm) and the TRIOS4 (0.22 ±0.09 mm) groups. However, the iTero, Modjaw, and TRIOS4 groups were not significantly different from each other (P>.05). The i700 group obtained the lowest trueness and precision values (0.40 ±0.22 mm) of all groups tested, followed by the Primescan grop (0.26±0.13 mm); however, the i700 and Primescan groups had significantly lower trueness and precision than only the iTero group (P<.05). Conclusions The trueness and precision of the maxillomandibular relationship recorded at the CR position were influenced by the different digital techniques tested.
科研通智能强力驱动
Strongly Powered by AbleSci AI