颈椎前路椎间盘切除融合术
有限元法
医学
电镀(地质)
融合
椎间盘切除术
外科
笼子
材料科学
口腔正畸科
下沉
颈椎
地质学
结构工程
腰椎
工程类
古生物学
哲学
构造盆地
语言学
地球物理学
作者
Maohua Lin,Stephen Z. Shapiro,James Doulgeris,Erik D. Engeberg,Chi-Tay Tsai,Frank D. Vrionis
标识
DOI:10.1016/j.spinee.2021.01.015
摘要
BACKGROUND CONTEXT Anterior cervical discectomy and fusion (ACDF) is widely used to treat patients with spinal disorders, where the cage is a critical component to achieve satisfactory fusion results. However, it is still not clear whether a cage with screws or without screws will be the best choice for long-term fusion as the micromotion (sliding distance) and subsidence (penetration) of the cage still take place repeatedly. PURPOSE This study aims to examine the effect of cage-screws on the biomechanical characteristics of the human spine, implanted cage, and associate hardware by comparing the micromotion and subsidence. STUDY DESIGN A finite element (FE) analysis study. METHODS A FE model of a C3-C5 cervical spine with ACDF was developed. The spinal segment was modeled with the removal of the anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), and discectomy was then implanted with a cage-screw system. Three models were analyzed: the first was the original spine (S1 model), the second, S2, was implanted with cages and anterior plating, and the third, S3, was implanted with a cage-screw system in addition to the anterior plate. All investigations were under 1 N•m in flexion, extension, lateral bending, and axial rotation situations. RESULTS Finite element analysis (FEA) demonstrated that range of motion (ROM) at C3-C4 in the S2 model was significantly reduced more than that in the S3 model, while the ROM at both C4-C5 in the S3 model was reduced more than that in the S2 model in all simulations. The ROM at C3-C5 in the S1 model was reduced by over 5° in the S2 and S3 models in all loading conditions. The micromotion and subsidence at all contacts of C3-C5 in the S3 model were lower than that in the S2 model in all flexion, extension, bending, and axial simulations. The subsidence and micromotion could be seen in the barrier area of the S2 model, while they occurred near the edge of the screw in the S3 model. CONCLUSIONS These results showed that the cage-screw and anterior plating combination has promising potential to reduce the risk of micromotion and subsidence of implanted cages in two or more level ACDFs. CLINICAL SIGNIFICANCE The use of double segmental fixation with cage-screw anterior plating combination constructs may increase the stiffness of the construct and reduce the incidence of clinical and radiographic pseudarthrosis following multilevel ACDF, which in turn, could decrease the need for revision surgeries or supplemental posterior fixation.
科研通智能强力驱动
Strongly Powered by AbleSci AI