医学
前交叉韧带重建术
半脱位
前交叉韧带
舱室(船)
外科
磁共振成像
骨科手术
核医学
放射科
海洋学
地质学
病理
替代医学
作者
Lin Lin,Haijun Wang,Yong‐Jian Wang,Jian Wang,Jing Liu,Jia‐Kuo Yu
标识
DOI:10.1177/03635465211072562
摘要
Passive anterior tibial subluxation (PATS) is often observed in patients with anterior cruciate ligament tears. Postoperative outcomes of double-bundle (DB) and single-bundle (SB) anterior cruciate ligament reconstruction (ACLR) with significant PATS (>6 mm) are unclear.DB-ACLR could achieve better stability and clinical outcomes than SB-ACLR in patients with PATS >6 mm.Cohort study; Level of evidence, 3.Retrospective analysis was peformed on 626 consecutive patients who underwent primary anatomic ACLR between October 2016 and November 2017. Anterior subluxation of the lateral and medial compartments in extension relative to the femoral condyles was measured on preoperative magnetic resonance imaging scans. Among patients who demonstrated significant PATS (>6 mm) in the lateral compartment, 54 who underwent DB-ACLR (study group) were matched to 54 who underwent SB-ACLR (control group). PATS, stability (pivot-shift test and KT-2000 arthrometer), the Lysholm score, and the International Knee Documentation Committee (IKDC) grade were investigated preoperatively and at 3- to 4-year follow-up.The preoperative mean PATS values in the lateral and medial compartments were not significantly different between groups (control vs study: lateral compartment, 8.1 ± 1.8 vs 8.5 ± 2.1 mm; medial compartment, 5.2 ± 1.9 vs 5.4 ± 1.9 mm; P > .05). Postoperatively, mean PATS values in the lateral and medial compartments of the study group were significantly improved as compared with the control group (control vs study: lateral compartment, 5.9 ± 2.8 vs 3.2 ± 4.1 mm; medial compartment, 3.7 ± 2.9 vs 1.4 ± 2.3 mm; P < .05). Significantly superior results were found for knee stability in the study group regarding the Lachman test (grade 0/1/2/3, study vs control: 29/22/3/0 vs 16/28/10/0; P = .031), pivot-shift test (grade 0/1/2/3, study vs control: 44/9/1/0 vs 30/19/5/0; P = .023), and KT-2000 arthrometer (study vs control: 2.5 ± 1.5 vs 3.9 ± 1.4 mm; P < .001). Clinical scores showed significantly better results in the study group in terms of IKDC score (study vs control: 87.9 ± 8.7 vs 81.2 ± 15.0; P = .01), Tegner activity score (study vs control: 6.0 ± 1.4 vs 4.9 ± 1.5; P < .001), and Lysholm score (study vs control: 91.7 ± 7.0 vs 86.3 ± 11.4; P = .004).DB-ACLR achieved better knee stability and clinical outcomes when compared with SB-ACLR in patients with PATS >6 mm at 3- to 4-year follow-up.
科研通智能强力驱动
Strongly Powered by AbleSci AI