冠状面
医学
超声科
一致性(知识库)
章节(排版)
三维超声
人工智能
核医学
口腔正畸科
计算机视觉
放射科
计算机科学
超声波
操作系统
作者
Jingnan He,Ligang Cui,Tao Chen,Xuemin Lyu,Jingmiao Yu,Wen Guo,Dandan Wang,Xiaoting Qin,Yibing Zhao,Shumin Zhang
摘要
An automatic evaluation technology based on artificial intelligence and three-dimensional ultrasonography (3D US) is proposed for hip US inspection plane selection. This study aimed to evaluate the consistency of the α angle as measured using 3D US to select the section plane and two-dimensional ultrasonography (2D US) to manually select the Graf image, as well as to explore the feasibility of diagnosing developmental dysplasia of the hip (DDH) using 3D US and reconstruction technology.A total of 216 infant hips were included and assessed by doctors using 3D US layer-by-layer. The researchers used a computer to identify the coronal images that met the Graf standard and then compared the αX values obtained with the αG values measured artificially by 2D US.Compared with 2D US, 3D US more clearly showed the relative positions of the ilium, ischia, and pubis. The measured α value of the optimal section obtained by 3D US showed good agreement with the measured α value of the standard Graf section.The artificial intelligence and 3D US-based automatic evaluation technology for section selection and inspection for DDH showed good agreement with the Graf method based on standard sections.
科研通智能强力驱动
Strongly Powered by AbleSci AI