医学
光学相干层析成像
光学相干断层摄影术
糖尿病性视网膜病变
血管造影
断层摄影术
眼科
荧光血管造影
放射科
情感(语言学)
视网膜病变
连贯性(哲学赌博策略)
验光服务
糖尿病
视网膜
物理
心理学
内分泌学
量子力学
沟通
作者
Ying Zhu,Yanqiao Zhang,Jay Wang,Yifan Lu,Rebecca Zeng,Raviv Katz,David M. Wu,Dean Eliott,Demetrios G. Vavvas,D. Husain,Joan W. Miller,Leo A. Kim,John B. Miller
标识
DOI:10.1016/j.ajo.2020.03.004
摘要
Purpose To compare different scan protocols of wide-field swept-source optical coherence tomography angiography (SS-OCTA) for the detection of diabetic retinopathy (DR) lesions. Design Comparison of diagnostic approaches. Methods A prospective, observational study was conducted at Massachusetts Eye and Ear from December 2018 to July 2019. Proliferative diabetic retinopathy (PDR), nonproliferative diabetic retinopathy (NPDR), and diabetic patients without DR were included. All patients were imaged using SS-OCTA using the following scan protocol: 3- × 3-mm Angio centered on the fovea; 6- × 6-mm Angio centered on the fovea and the optic disc; 15- × 9-mm Montage; and 12- × 12-mm Angio centered on the fovea and the optic disc. Images were independently evaluated by 2 graders for the presence or absence of DR lesions including microaneurysms, intraretinal microvascular abnormalities, neovascularization, nonperfusion areas, venous looping, and hard exudates. All statistical analyses were performed using commercial software. Results A total of 176 eyes in 119 participants were included in the study. The detection rate of neovascularization on 6- × 6-mm Angio centered on the fovea was approximately one-half that on 15- × 9-mm Montage (P < .05) imaging. Combining 6- × 6-mm Angio imaging centered on the fovea and the optic disc could increase the rate to approximately two-thirds (P < .05). The 12- × 12-mm Angio imaging centered on the combination of fovea and optic disc had detection rates comparable to those of 15- × 9-mm Montage imaging for all DR lesions (P > .05). For microaneurysms, 6- × 6-mm Angio had better performance than 15- × 9-mm Montage (P < .05). Conclusions Wide-field SS-OCTA images were useful in detecting DR lesions. The 12- × 12-mm Angio imaging centered on the fovea and on the optic disc may be an optimal balance between speed and efficacy for evaluation of DR in clinical practice. To compare different scan protocols of wide-field swept-source optical coherence tomography angiography (SS-OCTA) for the detection of diabetic retinopathy (DR) lesions. Comparison of diagnostic approaches. A prospective, observational study was conducted at Massachusetts Eye and Ear from December 2018 to July 2019. Proliferative diabetic retinopathy (PDR), nonproliferative diabetic retinopathy (NPDR), and diabetic patients without DR were included. All patients were imaged using SS-OCTA using the following scan protocol: 3- × 3-mm Angio centered on the fovea; 6- × 6-mm Angio centered on the fovea and the optic disc; 15- × 9-mm Montage; and 12- × 12-mm Angio centered on the fovea and the optic disc. Images were independently evaluated by 2 graders for the presence or absence of DR lesions including microaneurysms, intraretinal microvascular abnormalities, neovascularization, nonperfusion areas, venous looping, and hard exudates. All statistical analyses were performed using commercial software. A total of 176 eyes in 119 participants were included in the study. The detection rate of neovascularization on 6- × 6-mm Angio centered on the fovea was approximately one-half that on 15- × 9-mm Montage (P < .05) imaging. Combining 6- × 6-mm Angio imaging centered on the fovea and the optic disc could increase the rate to approximately two-thirds (P < .05). The 12- × 12-mm Angio imaging centered on the combination of fovea and optic disc had detection rates comparable to those of 15- × 9-mm Montage imaging for all DR lesions (P > .05). For microaneurysms, 6- × 6-mm Angio had better performance than 15- × 9-mm Montage (P < .05). Wide-field SS-OCTA images were useful in detecting DR lesions. The 12- × 12-mm Angio imaging centered on the fovea and on the optic disc may be an optimal balance between speed and efficacy for evaluation of DR in clinical practice.
科研通智能强力驱动
Strongly Powered by AbleSci AI