口腔矫治器
医学
阻塞性睡眠呼吸暂停
持续气道正压
多导睡眠图
置信区间
呼吸暂停
呼吸不足
睡眠呼吸暂停
麻醉
内科学
作者
Aarnoud Hoekema,Boudewijn Stegenga,Peter J. Wijkstra,Johannes H. van der Hoeven,A. F. Meinesz,Lambert G.M. de Bont
标识
DOI:10.1177/154405910808700917
摘要
In clinical practice, oral appliances are used primarily for obstructive sleep apnea patients who do not respond to continuous positive airway pressure (CPAP) therapy. We hypothesized that an oral appliance is not inferior to CPAP in treating obstructive sleep apnea effectively. We randomly assigned 103 individuals to oral-appliance or CPAP therapy. Polysomnography after 8-12 weeks indicated that treatment was effective for 39 of 51 persons using the oral appliance (76.5%) and for 43 of 52 persons using CPAP (82.7%). For the difference in effectiveness, a 95% two-sided confidence interval was calculated. Non-inferiority of oral-appliance therapy was considered to be established when the lower boundary of this interval exceeded -25%. The lower boundary of the confidence interval was -21.7%, indicating that oral-appliance therapy was not inferior to CPAP for effective treatment of obstructive sleep apnea. However, subgroup analysis revealed that oral-appliance therapy was less effective in individuals with severe disease (apnea-hypopnea index > 30). Since these people could be at particular cardiovascular risk, primary oral-appliance therapy appears to be supported only for those with non-severe apnea.
科研通智能强力驱动
Strongly Powered by AbleSci AI