Atrial fibrillation screening during automated blood pressure measurement—Comment on “Diagnostic accuracy of new algorithm to detect atrial fibrillation in a home blood pressure monitor”

医学 心房颤动 冲程(发动机) 无症状的 内科学 心脏病学 血压 华法林 心力衰竭 算法 计算机科学 机械工程 工程类
作者
Yi Chen,Lei Lei,Ji‐Guang Wang
出处
期刊:Journal of Clinical Hypertension [Wiley]
卷期号:19 (11): 1148-1151 被引量:12
标识
DOI:10.1111/jch.13081
摘要

With the increasing longevity and prevalence of cardiovascular disease, such as hypertension and chronic heart failure, there is an emerging epidemic of atrial fibrillation (AF) in almost all communities. According to the worldwide estimation in 2010, the prevalence of AF was 0.596% in men and 0.373% in women, and the estimated number of patients with AF worldwide was 33.5 million.1 A major complication of AF is embolic stroke. In a recent registry, AF accounted for a third of all ischemic strokes.2 Anticoagulation therapy with warfarin, a vitamin K antagonist,3 or non-vitamin K–dependent oral anticoagulants4 has proved to be highly effective in the prevention of stroke in AF. The challenge is that AF is usually asymptomatic or only mildly symptomatic and therefore significantly underdiagnosed. A quarter to a third of stroke cases related to AF occur as the first manifestation of AF.5 Nonetheless, screening is possible and with current technology can be cost-effective, if anticoagulation is successfully implemented. Screening for AF in persons older than 65 years may identify a prevalence of 1.4% with a single time point examination,6 3% with patient-activated ECG recordings over 2 weeks,7 and 10.4% with an even longer-term continuous ECG recordings technique.8 The consensus therefore is that AF should be screened in high-risk individuals, such as those older than 65 years, by all possible means.9 Current consensus on AF screening recommends various modalities for opportunistic or systematic screening of AF.9 In addition to a variety of ECG recording techniques, pulse measurement by manual palpation at the radial artery or by an automated oscillometric blood pressure (BP) monitor at the brachial or radial arterial sites is also recommended for AF screening.9 Pulse palpation is apparently cheap and simple but less accurate and more difficult for the elderly people, who have high prevalence of AF.10 On the other hand, automated oscillometric BP monitors may provide accurate information on irregularity of the cardiac rhythm by measuring the width and amplitude of pulse waves during BP measurement.10 Hypertension is a major risk factor for AF. Home BP monitoring with an automated device is recommended in patients with treated hypertension. AF screening using a BP monitor is becoming promising. Several models of BP monitors from various manufacturers were developed with an added function of irregular heartbeat detection (Table).11-17 Some of those devices were tested for accuracy in the detection of AF. Wiesel and colleagues11, 13, 15 have conducted a series of studies on AF detection during BP measurement. In a pioneering study, Wiesel and associates11 used an algorithm for the detection of AF during BP measurement on the basis of the last 10 pulses during cuff deflation. The irregularity index was defined as the standard deviation of the time intervals between successive heartbeats divided by the mean of the intervals. In a validation study against a standard 12-lead ECG, an irregularity index of 0.06 or greater was used as the threshold for the diagnosis of AF.11 This algorithm was integrated in a home BP monitor (modified Omron 712C, Omron). In 450 outpatients including 54 with AF diagnosed by ECG, the diagnostic sensitivity was 100% and specificity was 84% during a single BP measurement.11 The false-positive results were mainly seen in patients with frequent ectopic beats.11 The investigators then modified the algorithm by discarding pulse intervals of 25% shorter or 25% longer than the average and using the remaining time intervals for the calculation of the irregularity index. In a later study in 405 patients including 93 with AF diagnosed by ECG, the newer algorithm with a single BP measurement had a sensitivity and specificity of 95% and 86%, respectively.13 When three measurements were performed with at least two of the three indicating AF, the sensitivity and specificity rates were 97% and 89%, respectively.13 Several other studies12, 14-17 investigated BP monitors with an algorithm similar to the abovementioned modified algorithm and showed similar accuracy in the detection of AF, except one monitor that had a sensitivity of 30%.15 In general, these BP monitors had higher sensitivity and specificity in the detection of AF. Nonetheless, there is still some room for improvement, especially in reducing false-positive results. In this issue of the Journal, Kabutoya and colleagues18 reported a new algorithm for the detection of AF using a BP monitor. The authors believe that the new algorithm may further improve accuracy for the detection of AF during BP measurement. They defined a new index, called irregular pulse peak (IPP) 25, as the absolute difference between each interval of pulse peak and the average of the intervals of pulse peak ≥25% of the average of the intervals of pulse peak. If the number of IPP beats was ≥20% of the total number of pulses on two of the three BP measurements, AF could then be diagnosed. The sensitivity and specificity was 88% and 100%, respectively. If 20% and 15% was used as the threshold for the definition of IPP, the sensitivity was 94% and 100%, respectively, and the specificity was 100% for both thresholds. This new algorithm is different from the previous algorithm in several aspects.11 First, the new algorithm used all of the pulse waves during cuff deflation instead of the last 10 pulse intervals only. Second, pulse intervals of 25% shorter or longer than the average were included for the definition of the irregularity index IPP25 in the new algorithm but discarded in the previous algorithm. Third, for the diagnosis, the new algorithm counted the number of IPPs, whereas the previous algorithm used a fixed threshold of ≥0.06 of the irregularity index. The new algorithm was developed from a new angle to improve specificity in the detection of AF. However, cardiac arrhythmias other than AF were not included in this study.18 Both the current and previous algorithms were designed by assessing pulse rate irregularity. False-positive results can be present in patients with irregular heartbeats other than AF, such as various forms of premature beats and sick sinus syndrome. In the absence of other ECG-proven cardiac arrhythmias, the current study does not allow any inference on specificity in the presence of other cardiac arrhythmias. Indeed, the new algorithm may have false-positive results in patients with frequent premature complexes, because, as previously demonstrated, intervals of 25% shorter or longer than the average could also be attributable to premature beats.11 Whether adding another dimension of the pulse waves, such as pulse amplitude, for instance, would help improve accuracy in the detection of AF remains under investigation. We previously investigated the accuracy of devices with an algorithm accounting for both the variation of the pulse duration and the variation of the pulse amplitude.19 The sensitivity and specificity in the detection of AF and frequent ectopic beats were higher than devices with an algorithm accounting for the variation of the pulse duration only. Not only the algorithm but also the number of BP measurements may play a role. In a previous study, increasing the number of BP measurements from one to three and applying a majority rule (at least two of the three measurements showing AF) increased sensitivity from 95% to 97% and specificity from 86% to 89% for the detection of AF.13 A similar improvement was observed in another study in sensitivity from 93% to 100% and specificity from 83% to 89%.12 The AF detection function should probably become available in all BP monitors for home use. Preferably, the detection can be automatically transmitted to a clinical setting for decisions of further AF screening and eventually for the diagnosis and treatment of AF. With these technical capabilities, large-scale outcome studies on AF screening should be conducted for the identification of AF and the prevention of stroke.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
1秒前
甘草三七完成签到,获得积分10
4秒前
FashionBoy应助科研通管家采纳,获得10
6秒前
6秒前
慕青应助科研通管家采纳,获得30
6秒前
打打应助科研通管家采纳,获得10
6秒前
6秒前
multimodal完成签到 ,获得积分10
6秒前
7秒前
Evian79167发布了新的文献求助30
7秒前
阳光绿柏完成签到,获得积分10
10秒前
12秒前
12秒前
YYJ完成签到 ,获得积分10
13秒前
Channingh发布了新的文献求助10
13秒前
江南之南完成签到 ,获得积分10
13秒前
wsb76完成签到 ,获得积分10
14秒前
Evian79167完成签到,获得积分10
15秒前
20秒前
炮哥kiki完成签到 ,获得积分10
21秒前
时尚的画笔完成签到,获得积分20
22秒前
23秒前
26秒前
半夏完成签到 ,获得积分10
27秒前
青空完成签到,获得积分20
27秒前
27秒前
30秒前
aikeyan完成签到 ,获得积分10
31秒前
greedyfree完成签到 ,获得积分10
33秒前
YBR完成签到 ,获得积分10
34秒前
铃槐完成签到,获得积分10
34秒前
37秒前
OrthoDW发布了新的文献求助10
42秒前
平淡的天思完成签到,获得积分10
42秒前
44秒前
蔺无双发布了新的文献求助10
44秒前
46秒前
47秒前
无趣世界zZ完成签到,获得积分10
47秒前
毛毛完成签到,获得积分10
49秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Einführung in die Rechtsphilosophie und Rechtstheorie der Gegenwart 1500
Binary Alloy Phase Diagrams, 2nd Edition 1000
青少年心理适应性量表(APAS)使用手册 700
Air Transportation A Global Management Perspective 9th Edition 700
Socialization In The Context Of The Family: Parent-Child Interaction 600
DESIGN GUIDE FOR SHIPBOARD AIRBORNE NOISE CONTROL 600
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 内科学 生物化学 物理 计算机科学 纳米技术 遗传学 基因 复合材料 化学工程 物理化学 病理 催化作用 免疫学 量子力学
热门帖子
关注 科研通微信公众号,转发送积分 4994344
求助须知:如何正确求助?哪些是违规求助? 4241931
关于积分的说明 13215274
捐赠科研通 4037464
什么是DOI,文献DOI怎么找? 2209095
邀请新用户注册赠送积分活动 1219913
关于科研通互助平台的介绍 1138472