亲爱的研友该休息了!由于当前在线用户较少,发布求助请尽量完整地填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!身体可是革命的本钱,早点休息,好梦!

[Comparison of keratometric measurements obtained by the Verion image guided system with the IOLMaster and the Pentacam before cataract extraction surgery].

角膜曲率计 Scheimpflug原理 眼科 医学 散光 白内障手术 角膜地形图 验光服务 角膜 光学 物理
作者
Juan Wu,Ping Gao,Fan Jin-xue,T T Li,F Liu
出处
期刊:PubMed 卷期号:56 (1): 47-52 被引量:4
标识
DOI:10.3760/cma.j.issn.0412-4081.2020.01.012
摘要

Objective: To compare the keratometric measurements of the Verion image guided system with the partial coherence interferometry (IOLMaster700) and the scheimpflug corneal topography (Pentacam). Methods: In this cross-sectional study, 146 eyes of 88 patients [mean age, (69±10) years; 62 eyes of male patients and 84 eyes of female patients] with cataract were examined before cataract extraction and IOL implantation surgery in the Tenth People's Hospital Affiliated to Tongji University from January 2016 to March 2017. Corneal curvature values acquired by the Verion optical imaging system were compared with the IOLMaster700 and the Pentacam. Keratometric data, magnitude of astigmatism, and steep astigmatic axis measurements from all three instruments were also compared. According to the steep axis of astigmatism, the eyes were divided into groups of with the rule (WTR), against the rule (ATR), and oblique astigmatism. The parameter differences between the Verion and the other devices in the three groups were analyzed. The data were evaluated using repeated measures analysis of variance and Bland-Altman plots. Results: The values of steep keratometry (Ks) of the Verion, IOLMaster700, and Pentacam were (44.60±1.32), (44.73±1.37), (44.43±1.35) D, respectively. The values of flat keratometry (Kf) of the Verion, IOLMaster700, and Pentacam were (43.51±1.41), (43.51±1.52), (43.40±1.45) D, respectively. The values of mean keratometry (Km) of the Verion, IOLMaster700, and Pentacam were (44.60±1.32), (44.12±1.35), (43.92±1.34) D, respectively. The values of astigmatism magnitude were (1.09±0.87), (1.24±1.02), (1.04±0.80) D, respectively. The F values were 1.81, 0.31, 0.93 and 2.22 in relation to Ks, Kf, Km and corneal astigmatism magnitude among the three instruments, respectively (all P>0.05). The 95% confidence intervals of Kf, Ks and astigmatism magnitude between the Verion and the other two devices were -1.10 to 0.80 D, -0.55 to 0.88 D; -1.10 D to 1.10 D, -0.80 to 1.04 D; -1.21 to 0.90 D, -0.92 to 1.02 D. The outcomes were considered acceptable. There were no statistically differences in steep astigmatic axis measurements between the Verion and the other two instruments among the WTR (62 eyes), ATR (45 eyes) and oblique (15 eyes) groups (F=0.63, 0.37; P=0.54, 0.72, respectively). Conclusions: The Verion image guided system is a reliable system for the measurement of keratometry values and astigmatism. The keratometric power, magnitude and steep axis of astigmatism have no significant difference, and there is a good agreement among the Verion, IOL Master 700, and Pentacam. (Chin J Ophthalmol, 2020, 56: 47-52).目的: 比较Verion数字导航系统与IOLMaster700、Pentacam在白内障摘除手术联合人工晶状体(IOL)植入术前测量角膜散光的差异及一致性。 方法: 横断面研究。收集2016年1月至2017年3月于同济大学附属第十人民医院眼科拟行Verion数字导航系统辅助下的超声乳化白内障吸除联合IOL植入术的88例(146只眼)白内障患者[年龄(69±10)岁;男性62只眼,女性84只眼],术前分别用上述3种仪器测量陡峭轴角膜曲率(Ks)、平坦轴角膜曲率(Kf)、平均角膜曲率(Km)、角膜散光度数、陡峭轴散光轴位。将3种方法测量的陡峭轴散光轴位按照散光轴位方向分为顺规散光组、逆规散光组和斜向散光组。3种仪器间测量结果及组间散光轴位差值的比较采用重复测量的方差分析,一致性检验采用Bland-Altman分析。 结果: Verion、IOLMaster 700和Pentacam的Ks检测值分别为(44.60±1.32)、(44.73±1.37)、(44.43±1.35)D,Kf检测值分别为(43.51±1.41)、(43.51±1.52)、(43.40±1.45)D,Km检测值分别为(44.06±1.30)、(44.12±1.35)、(43.92±1.34)D,散光度数分别为(1.09±0.87)、(1.24±1.02)、(1.04±0.80)D,3种方法间检测值差异均无统计学意义(F=1.81,0.31,0.93,2.22;均P>0.05)。Bland-Altman分析显示Verion与IOLMaster700、Verion与Pentacam测量Ks一致性比较的95%可信区间分别为-1.10~0.80 D、-0.55~0.88D;Kf一致性比较的95%可信区间分别为-1.10~1.10 D、-0.80~1.04 D;角膜散光度一致性比较的95%可信区间分别为-1.21~0.90 D、-0.92~1.02 D,3种设备计算Ks、Kf、角膜散光幅度一致性均在临床可接受范围。顺规散光组(62只眼)、逆规散光组(45只眼)和斜向散光组(15只眼)组间陡峭轴散光轴位的Verion与IOLMaster700、Verion与Pentacam测量差值差异均无统计学意义(F=0.63,0.37;均P>0.05)。 结论: Verion与IOLMaster700、Pentacam在白内障摘除联合IOL植入术前测量角膜曲率、散光度数和轴位方面无明显差别,3种测量方法的一致性较好。(中华眼科杂志,2020,56:47-52).

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
量子星尘发布了新的文献求助10
3秒前
热情依白应助读书的时候采纳,获得10
17秒前
Mia233完成签到 ,获得积分10
26秒前
晞暝关注了科研通微信公众号
36秒前
晞暝发布了新的文献求助10
53秒前
热情依白应助读书的时候采纳,获得10
1分钟前
1分钟前
领导范儿应助Ahan采纳,获得10
1分钟前
激动的似狮完成签到,获得积分0
1分钟前
1分钟前
2分钟前
沉默念瑶完成签到 ,获得积分10
2分钟前
热情依白应助读书的时候采纳,获得10
2分钟前
2分钟前
siv发布了新的文献求助10
2分钟前
晞暝完成签到,获得积分10
2分钟前
2分钟前
王志新完成签到 ,获得积分10
2分钟前
3分钟前
3分钟前
3分钟前
3分钟前
文艺的乌龟完成签到,获得积分20
3分钟前
Criminology34应助文艺的乌龟采纳,获得30
3分钟前
3分钟前
4分钟前
4分钟前
我是老大应助nullchuang采纳,获得10
4分钟前
4分钟前
4分钟前
Ji发布了新的文献求助30
4分钟前
nullchuang发布了新的文献求助10
4分钟前
4分钟前
桐桐应助何88888888采纳,获得10
4分钟前
Ji完成签到,获得积分10
4分钟前
4分钟前
Ahan发布了新的文献求助10
4分钟前
花城诚成发布了新的文献求助10
5分钟前
量子星尘发布了新的文献求助10
5分钟前
5分钟前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
2025-2031全球及中国金刚石触媒粉行业研究及十五五规划分析报告 9000
Encyclopedia of the Human Brain Second Edition 8000
The Cambridge History of China: Volume 4, Sui and T'ang China, 589–906 AD, Part Two 1000
The Composition and Relative Chronology of Dynasties 16 and 17 in Egypt 1000
Real World Research, 5th Edition 800
Qualitative Data Analysis with NVivo By Jenine Beekhuyzen, Pat Bazeley · 2024 800
热门求助领域 (近24小时)
化学 材料科学 生物 医学 工程类 计算机科学 有机化学 物理 生物化学 纳米技术 复合材料 内科学 化学工程 人工智能 催化作用 遗传学 数学 基因 量子力学 物理化学
热门帖子
关注 科研通微信公众号,转发送积分 5688044
求助须知:如何正确求助?哪些是违规求助? 5062729
关于积分的说明 15193594
捐赠科研通 4846395
什么是DOI,文献DOI怎么找? 2598847
邀请新用户注册赠送积分活动 1550933
关于科研通互助平台的介绍 1509501